Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Overview
The Triconex 9563-810NJ Digital Input Termination Panel is a vital component in the Triconex safety and control systems. It is designed to connect and interface the field wiring to the Tricon system’s digital input modules, facilitating the transmission of input signals from external devices into the control system. This termination panel features 16 points for input signals and is commonly used in industrial environments where safety and operational efficiency are paramount.
This product is part of the Triconex range, offering flexibility in digital input configuration and maintaining high standards of reliability and performance in demanding conditions. Whether in a simple or complex control system setup, the Triconex 9563-810NJ ensures a seamless and secure connection between external field equipment and the control system.
Product Features
-
Digital Input Configuration:
- The 9563-810NJ panel supports a 16-point commoned digital input, which helps in collecting data from various field devices such as sensors, switches, or other digital input devices.
-
Voltage Rating:
- Operating with a nominal voltage of 24 VDC, the panel ensures compatibility with a wide range of field devices.
-
High Durability:
- Built to withstand industrial environments, the termination panel is housed in a DIN-rail compatible plastic housing, offering easy installation and robust protection for the internal components.
-
Modular Design:
- The product allows for easy replacement or removal of I/O modules without disturbing the field wiring, ensuring minimal downtime during maintenance.
-
Simplified Maintenance:
- The use of compression terminals for field wiring simplifies the connection process and makes maintenance easier compared to more complex systems.
-
Temperature and Safety Compliance:
- The panel is designed to operate in harsh industrial environments, maintaining functionality even under high stress, while complying with industry standards for safety.
Product Advantages
- High Density: With 16 input points, the panel offers high-density field connections, making it ideal for installations that require multiple digital input signals in a compact space.
- Easy Installation: The 9563-810NJ connects easily to a Tricon backplane via an interface cable, which is pre-configured for direct connection to the backplane, minimizing the complexity of wiring.
- Reliability: As a part of the Triconex system, the 9563-810NJ is built to the same high reliability standards as other Triconex products, ensuring consistent operation in safety-critical applications.
- Cost Efficiency: The modular design means that maintenance or upgrades can be done without requiring a complete system overhaul, offering cost savings in long-term operation.
Product Specifications
Parameter | Value |
---|---|
Model | 9563-810NJ |
Input Type | 16-point commoned digital inputs |
Nominal Voltage | 24 VDC |
Connector Type | DIN-rail compatible |
Cable Type | Interface cable included (3 meters standard) |
Mounting Type | DIN rail compatible |
Dimensions | 114.3 × 127 × 107.95 mm |
Weight | 0.38 kg |
Product Applications
The Triconex 9563-810NJ Digital Input Termination Panel is ideal for use in applications requiring secure, reliable digital signal acquisition. Typical fields of application include:
- Industrial Automation: Used in manufacturing plants to connect field devices to control systems.
- Process Control: Employed in chemical or petrochemical plants where monitoring and control of safety-critical inputs is essential.
- Power Generation: Used in the automation of power plants, ensuring safe and efficient control of digital inputs from various equipment.
- Safety Systems: Suitable for systems where operational safety is critical, such as in nuclear or gas installations, ensuring proper signal input to safety and control systems.
Recommended Related Models
Below are six related models from the same series or with similar specifications for different configurations:
Model | Input Type | Voltage Rating | Points | Features |
---|---|---|---|---|
9561-810 | 16-point commoned digital inputs | 115 VDC | 16 | Basic model for digital inputs |
9562-810 | 16-point commoned digital inputs | 48 VDC | 16 | Suitable for lower-voltage systems |
9565-810 | 32-point commoned digital inputs | 48 VDC | 32 | High-density version |
9566-710 | 32-point commoned digital inputs | 24 VDC | 32 | High-density with extended range |
9570-610 | 32-point commoned digital inputs | 24 VDC | 32 | Fail-safe design |
9572-610 | 16-point commoned digital inputs | 24 VDC | 16 | Basic high-reliability model |
Popular Triconex Models
Here are six popular models from the Triconex brand that are widely used in the industry:
Model | Type | Voltage Rating | Input/Output Points | Features |
---|---|---|---|---|
3501E | Digital Input Module | 115 VAC | 32 | For larger systems |
3601E | Digital Output Module | 115 VAC | 16 | High-performance control |
3503E | Digital Input Module | 24 VDC | 32 | For industrial automation |
3604E | Digital Output Module | 24 VDC | 16 | For control of high-power devices |
3505E | Digital Input Module | 24 VDC | 32 | Low-threshold input module |
3614E | Digital Output Module | 24 VDC | 8 | For low-power output requirements |
FAQ
FAQs (Frequently Asked Questions)
Q1: What is the primary function of the Triconex 9563-810NJ Digital Input Termination Panel?
A1: The primary function is to provide a reliable connection for field digital inputs to the Tricon system, allowing for easy signal transmission and interface with external devices.
Q2: What voltage does the 9563-810NJ panel support?
A2: It supports a nominal voltage of 24 VDC.
Q3: Can I use this panel with sensors?
A3: Yes, the panel is designed to connect digital input signals from sensors, switches, and other field devices to the Tricon system.
Q4: Is the panel suitable for use in hazardous environments?
A4: While the 9563-810NJ panel is designed for industrial use, specialized panels like the nonincendive panels are recommended for hazardous locations.
Q5: What is the maximum number of input points this panel supports?
A5: The 9563-810NJ supports up to 16 digital input points.
Q6: How is the panel installed?
A6: The panel is mounted on a DIN rail and connects to the Tricon system via an interface cable, which is included with the panel.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.