Welcome to TilGames!

Triconex 4409 Safety Manager Module

Triconex 4409 Safety Manager Module

Manufacturer:Triconex

Product Number:Triconex 4409

Product Type:Safety Manager Module

Origin:USA

Dimensions:21 x 405 x 400 mm

Weight:2.3 kg

Views:1

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
https://www.tilgames.com/wp-content/uploads/2025/04/Triconex-4409-2.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/Triconex-4409-1.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/Triconex-4409-3.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/Triconex-4409-4.jpg
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Triconex 4409 Safety Manager Module (SMM) Overview

The Triconex 4409 Safety Manager Module (SMM) serves as an essential interface between the Tricon controller and the Honeywell Universal Control Network (UCN), one of the core networks of the TDC 3000 Distributed Control System (DCS). This module allows seamless communication between Tricon and the Honeywell DCS system, transmitting critical safety data while supporting high network data rates across various applications within the system.


Product Features and Functions

  • Critical I/O Handling: The SMM is responsible for managing critical I/O points and sending the results to the DCS.

  • Tricon Alarm Handling: It processes alarms from the Tricon and propagates them to user-defined destinations in the DCS, such as consoles and printers.

  • Aliased Data Management: The module reads and writes aliased data to meet DCS requests.

  • Tricon Diagnostics Display: It fetches and displays Tricon diagnostics through the DCS interface.

  • Write Protection: Ensures the safety system remains locked from modifications initiated by the DCS.

  • Time Synchronization: Time synchronization is provided from the DCS master clock to ensure accurate operation.

  • Peer-to-Peer Communication: Facilitates communication between multiple Tricon safety systems in large plant setups.

  • Event Sequence Transmission: It sends Tricon event data to Universal Stations for display and History Modules for recording, aiding in the identification of plant trips and increasing process uptime.

  • Hot-Spare Capability: Guarantees uninterrupted communication with Honeywell networks, even during module failures.


Product Specifications

Parameter Specification
Model Number 4409
UCN Ports 2 isolated (AC coupled)
UCN Data Rate 5 MBytes per second
Status Indicators PASS, FAULT, ACTIVE, LOW BATT, SPARE RDY
Power Module Load < 20 Watts
Isolation 500 VDC
UCN Port A/B Active indicators
Debug Port DB-25P Connector (for Triconex & Honeywell use)
Diagnostic Info Display Alphanumeric 4-character display
Power Consumption < 20 watts
Module Size 21 x 405 x 400 mm
Weight 2.3 kg

Applications

The Triconex 4409 SMM is specifically designed for use in:

  • Process Safety Systems: Managing critical I/O points for the safety control systems of industrial processes.

  • Alarm and Data Integration: Integrating Tricon alarms and diagnostic data within Honeywell DCS environments.

  • Event Monitoring and Troubleshooting: Enhancing system uptime by helping determine the cause of plant trips through Sequence of Events functionality.


Advantages

  • High Availability: With hot-spare capability and peer-to-peer communication, it ensures continuous operation even in case of module failure.

  • Comprehensive Data Management: Handles both critical I/O points and diagnostics, ensuring seamless integration with Honeywell’s control systems.

  • Improved Process Uptime: Through event sequence tracking and diagnostics display, it reduces downtime by enabling quick troubleshooting.

  • Enhanced Safety: Write protection prevents unauthorized changes to the safety system, ensuring the integrity of the process control environment.


Related Models in the Same Series

Here are six related models within the Triconex series that provide similar functionality:

Model Number Description
4408 Triconex Network Communication Module (NCM)
4407 Triconex Enhanced Intelligent Communication Module (EICM)
4401 Triconex Communication Module (TCM)
4509 Triconex Hiway Interface Module (HIM)
4609 Triconex Advanced Communication Module (ACM)
4329 Triconex Network Communication Module (NCM)

Popular Triconex Models

Here are six of the most popular Triconex models used in industrial control systems:

Model Number Description Input/Output Type Power Consumption Module Size
3501E Digital Input Module (TMR) Digital 10W 21 x 400 x 350 mm
3504E High-Density Digital Input Module (TMR) Digital 12W 21 x 405 x 350 mm
3805E Analog Output Module (4-20 mA) Analog 15W 21 x 400 x 370 mm
3700A Analog Input Module (0-5V DC, TMR) Analog 10W 21 x 400 x 360 mm
3601E Digital Output Module (115 VAC) Digital 10W 21 x 400 x 350 mm
4119A Enhanced Intelligent Communication Module (EICM) Communication 15W 21 x 405 x 370 mm
FAQ

Frequently Asked Questions (FAQ)

Q1: What is the purpose of the Triconex 4409 Safety Manager Module?
A1: The SMM interfaces a Tricon controller with a Honeywell DCS, managing critical I/O, alarms, and diagnostics, and ensuring seamless communication.

Q2: Can the Triconex 4409 SMM communicate with other Tricon controllers?
A2: Yes, it supports peer-to-peer communication for plants with multiple Tricon safety systems.

Q3: What is the data rate supported by the UCN ports?
A3: The UCN ports support a data rate of 5 MBytes per second.

Q4: How does the SMM ensure system reliability?
A4: Through features like hot-spare capability, peer-to-peer communication, and write protection, ensuring uninterrupted operation.

Q5: What types of status indicators are available on the SMM?
A5: The module has indicators for PASS, FAULT, ACTIVE, LOW BATT, SPARE RDY, and more.

Q6: What is the size and weight of the Triconex 4409 module?
A6: The module measures 21 x 405 x 400 mm and weighs 2.3 kg.

Q7: How does the SMM handle event data from Tricon controllers?
A7: It transmits Sequence of Events data to operator workstations or history modules, helping identify causes of plant trips.

Q8: What is the power consumption of the Safety Manager Module?
A8: The module has a low power consumption of under 20 watts.

Tags
Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message