Product Overview – Schneider TSXAEY800 Modicon Analog Input Module
– Product Description
The Schneider TSXAEY800 is a high-level analog input module designed for the Modicon Premium Automation platform. It supports multiple analog signal types, including current and voltage, and offers fast acquisition and high-resolution conversion for precise process control. The module integrates seamlessly into Schneider Electric’s EcoStruxure™ architecture and is suitable for demanding industrial applications.
– Technical Specifications
Parameter | Description |
---|---|
Range of Product | Modicon Premium Automation Platform |
Product Type | Analog Input Module |
Analog Input Channels | 8 |
Input Types | 0–20 mA, 4–20 mA, 0–5 V, 1–5 V, 0–10 V, ±10 V |
Analog/Digital Conversion | 12-bit resolution |
Nominal Read Cycle Time | 27 ms |
Fast Read Cycle Time | 3 ms + 3 ms per channel |
Measurement Error (25 °C) | ±0.15% to ±0.25% depending on range |
Measurement Error (0–60 °C) | ±0.22% to ±0.41% |
Channel Isolation (to bus/ground) | 1000 Vrms |
Electrical Connection | SUB-D 25-pin connector |
Input Overvoltage Protection | ±15 V (state 0), ±30 V (state 1) |
Overcurrent Protection | ±30 mA (state 1, 250 kΩ) |
Marking | CE |
Current Consumption | 270 mA at 5 V DC |
Module Format | Standard, rack-mounted |
Dimensions | 55 x 180 x 260 mm |
Net Weight | 0.31 kg (0.68 lb) |
Protection Rating | IP20 |
Pollution Degree | 2 |
Operating Temperature | 0 to 60 °C (32 to 140 °F) |
Storage Temperature | -25 to 70 °C (-13 to 158 °F) |
Operating Altitude | Up to 2000 m (6562 ft) |
Relative Humidity (Operation) | 10–95% non-condensing |
Standards Compliance | IEC 1131, UL508 |
Certifications | CE, DNV, RINA, GL, BV, LR, RMRS, ABS |
Protective Coating | TC (Tropicalization Class) |
– Key Features
-
Supports both voltage and current analog input signals.
-
Rapid acquisition time enhances real-time monitoring capabilities.
-
High signal integrity with robust isolation between channels and system.
-
Overvoltage and overcurrent protection ensures durability.
-
Plug-and-play integration with Premium PLC architecture.
-
25-pin Sub-D connector enables efficient and safe wiring.
-
Compact standard format for easy rack installation.
– Advantages
-
Versatility: Wide range of input signal compatibility (voltage & current).
-
Precision: Accurate readings with low measurement error and fast response.
-
Reliability: Built-in protection mechanisms and certified quality standards.
-
Compatibility: Fully integrates into Schneider Premium and EcoStruxure systems.
-
Robustness: Designed for industrial environments with strong EMC performance.
-
Ease of Maintenance: LED diagnostics and structured wiring simplify upkeep.
– Applications
-
Process instrumentation and monitoring
-
Industrial automation systems
-
Power and energy management
-
Factory automation (e.g., chemical, food & beverage, manufacturing)
-
SCADA-integrated systems for analog signal processing
-
Remote monitoring and data acquisition (DAQ) systems
– Latest Report or Release Title
“Analog Input/Output Modules User Manual for Premium and Atrium Platforms Using EcoStruxure™ Control Expert – 12/2018 Edition”
This official document from Schneider Electric outlines installation, wiring, configuration, and diagnostics for TSXAEY800 and related modules.
– Recommended Related Models from the Same Series
Model | Description | Input Type | Channels | Resolution | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|---|
TSXAEY420 | Analog Input Module | Voltage/Current | 8 | 12-bit | 55 x 180 x 260 | 0.3 |
TSXAEY810 | Analog Input Module | Voltage/Current | 8 | 12-bit | 55 x 180 x 260 | 0.3 |
TSXAEY414 | Analog Input Module | Thermocouple/PT100 | 4 | 16-bit | 55 x 180 x 260 | 0.35 |
TSXAEY1600 | Analog Input Module | Voltage/Current | 16 | 12-bit | 55 x 180 x 260 | 0.38 |
TSXAEY1614 | Analog Input Module | Thermocouple/PT100 | 4 | 16-bit | 55 x 180 x 260 | 0.37 |
TSXASY800 | Analog Output Module | Voltage/Current | 8 | 14-bit | 55 x 180 x 260 | 0.3 |
– Popular Schneider Models
Model | Type | Application | Channels | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|
BMXAMI0810 | Analog Input Module | Modicon X80 | 8 | 32 x 100 x 115 | 0.25 |
BMXAMO0210 | Analog Output Module | Modicon X80 | 2 | 32 x 100 x 115 | 0.24 |
BMXAMM0600 | Analog Mixed I/O | Modicon X80 | 6 | 32 x 100 x 115 | 0.28 |
TSXPSY2600 | Power Supply Module | Modicon Premium | — | 55 x 180 x 150 | 1.4 |
TSXP572634M | Processor Module | Modicon Premium CPU | — | 55 x 180 x 260 | 0.85 |
BMXNOE0110 | Ethernet Communication | Network Interface for Modicon X80 | — | 32 x 100 x 115 | 0.2 |
FAQ
– Frequently Asked Questions (FAQ)
Q1: What types of signals can the TSXAEY800 module handle?
A1: It supports analog voltage inputs (0–5 V, 1–5 V, 0–10 V, ±10 V) and current inputs (0–20 mA, 4–20 mA).
Q2: Can TSXAEY800 be used with both 2-wire and 4-wire sensors?
A2: Yes, with appropriate wiring configurations and external shunt resistors if needed.
Q3: What is the accuracy level of the module?
A3: At 25 °C, the accuracy ranges from ±0.15% to ±0.25% depending on input type.
Q4: Does the module support channel isolation?
A4: Yes, each channel is isolated at 1000 Vrms from the bus and ground.
Q5: What type of connector is used for signal input?
A5: A 25-pin SUB-D connector is used for channel signal wiring.
Q6: Is the module compatible with EcoStruxure Control Expert?
A6: Yes, it is designed for use within the EcoStruxure Control Expert environment.
Q7: Can the TSXAEY800 be installed in any slot of the rack?
A7: It can be installed in any slot except the first two (reserved for power supply and processor).
Q8: What protective measures are built into the module?
A8: The module includes overvoltage and overcurrent protection and complies with EMC and industrial safety standards.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.