Welcome to TilGames!

Schneider TSXAEY414 Modicon Analog Input Module

Schneider TSXAEY414 Modicon Analog Input Module

Manufacturer:Schneider

Product Number:TSXAEY414

Product Type:Modicon Analog Input Module

Origin:France

Dimensions:55 x 180 x 260 mm

Weight:0.35 kg

Views:29

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
https://www.tilgames.com/wp-content/uploads/2025/04/TSXAEY414-1.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/TSXAEY414-2.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/TSXAEY414-3.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/TSXAEY414-4.jpg
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Product Description

The Schneider TSXAEY414 is a high-performance analog input module designed for the Modicon Premium Automation Platform. This module offers multi-range isolated analog input capability with support for both low and high-level signals. It features 4 independent isolated channels, supporting a broad spectrum of input types including voltage, current, resistance, thermocouples, and thermoprobes. With robust electrical isolation, precise 16-bit analog-to-digital conversion, and advanced cold junction compensation, the TSXAEY414 ensures reliable acquisition of analog signals for critical process control applications.


Product Parameters

Parameter Value
Range of Product Modicon Premium Automation Platform
Product Type Analog Input Module
Number of Analog Inputs 4
Input Types Voltage, Current, Thermocouple, Thermoprobe, Resistance
Supported Voltage Ranges ±10 V, 0–10 V, ±5 V, 0–5 V, 1–5 V
Supported Current Ranges 0–20 mA, 4–20 mA (via external 250 Ω shunt)
Thermocouple Types B, E, J, K, L, N, R, S, T, U
Thermoprobe Support Pt100, Pt1000, Ni1000 (2-wire and 4-wire)
Resistance Measurement 0–400 Ω, 0–3850 Ω
Special Input Range -13 to +63 mV
Analog/Digital Conversion 16-bit
Nominal Read Cycle Time 550 ms
Isolation Between Channels 2830 Vrms
Isolation to Bus and Ground 1780 Vrms
Input Overvoltage Protection ±15 V to ±30 V (with shunt)
Input Impedance 10 MΩ for voltage inputs
Power Consumption 660 mA at 5 V DC
Module Format Standard, single-slot module
Electrical Connection Screw terminal block (TSX BLY 01)
Dimensions (W x H x D) 55 x 180 x 260 mm
Net Weight 0.35 kg
Environmental Standards IEC 584, IEC 751, DIN 43710, NFC 42-330
Operating Temperature 0…60 °C
Storage Temperature -25…70 °C
Relative Humidity 10–95 % (operation), 5–95 % (storage)
Operating Altitude 0…2000 m
IP Degree of Protection IP20
Certifications CE, DNV, BV, ABS, RMRS, RINA, GL, LR

Product Features

  • Multi-range Capability: Each of the 4 isolated input channels can be configured individually to support voltage, current, thermocouple, thermoprobe, or resistance inputs.

  • High Accuracy: 16-bit resolution provides detailed and accurate analog signal conversion.

  • Built-in Isolation: Electrical isolation ensures minimal interference between channels, enhancing signal integrity.

  • Wide Sensor Compatibility: Compatible with a large variety of sensors including thermocouples and resistance temperature detectors (RTDs).

  • Compact Integration: Designed in a single-slot standard format compatible with all positions in the TSX RKY rack (except for PS and CPU slots).


Product Advantages

  • Flexible Input Configuration: Supports 23 signal types per channel, enabling high adaptability for various process monitoring needs.

  • Robust Environmental Resistance: Operates reliably under a wide range of temperature and humidity conditions.

  • Enhanced Safety: High isolation voltage and overvoltage protection safeguard both the module and the PLC system.

  • Simplified Wiring: Utilizes the TSX BLY 01 screw terminal block for secure and straightforward sensor connections.

  • Cold Junction Compensation: Available both internally and externally using a class A Pt100 probe.


Applications

  • Industrial Automation – Analog data acquisition from process sensors (e.g., temperature, pressure, flow).

  • Energy Management – Monitoring thermocouples and RTDs in power plants.

  • HVAC Systems – Precise environmental sensing and control.

  • Chemical and Pharmaceutical Manufacturing – For thermowell and mV range measurements.

  • Food and Beverage Processing – Temperature monitoring in compliance with industry regulations.


Latest Reports / News Headlines

  • “Schneider TSXAEY414 Now Supported in EcoStruxure Hybrid DCS”

  • “Enhanced Accuracy of TSXAEY414 in High-Reliability Industrial Applications”

  • “Modicon Premium Analog Modules Reach New Standard in I/O Flexibility”


Related Models (Same Series or Compatible)

Model Channels Signal Type Connector Type Notes
TSXAEY420 4 Voltage, Current Sub-D 25-pin Compact module, similar function
TSXAEY800 8 Voltage, Current Sub-D 25-pin Higher channel count
TSXAEY810 8 Voltage, Current Sub-D 25-pin Variant of AEY800
TSXAEY1600 16 Thermocouples Dual Sub-D 25-pin High-density thermocouple module
TSXAEY1614 16 Thermocouples, Resistance Dual Sub-D 25-pin Expanded range for temperature input
TSXASY410 4 Analog Output Screw Terminal Paired output module for TSXAEY414

Popular Schneider Models (Cross-family Recommendations)

Model Type I/O Count Application Dimensions (mm) Weight (kg)
BMXAMI0810 Analog Input 8 AI Modicon X80 universal input 32 x 100 x 95 0.3
BMXAMO0410 Analog Output 4 AO High-resolution output control 32 x 100 x 95 0.3
BMXCPS3500H Power Supply Redundant power for X80 racks 64 x 110 x 124 0.65
TSXPSY2600 Power Supply For TSX57 racks 80 x 180 x 180 1.4
TSX3721001 PLC CPU Entry-level CPU 55 x 180 x 260 0.35
TSXP57103M Processor Module Modicon Premium CPU 55 x 180 x 260 0.35
FAQ

Frequently Asked Questions (FAQs)

Q1: What types of input signals does the TSXAEY414 support?
A1: It supports voltage (±10 V, ±5 V, 0–10 V, 0–5 V, 1–5 V), current (0–20 mA, 4–20 mA with external shunt), thermocouples (B, E, J, K, L, N, R, S, T, U), resistance (0–400 Ω, 0–3850 Ω), and thermoprobes (Pt100, Pt1000, Ni1000).

Q2: Are the input channels electrically isolated from each other?
A2: Yes. Each of the four channels is fully isolated with 2830 Vrms channel-to-channel isolation.

Q3: Does the TSXAEY414 include cold junction compensation?
A3: Yes, both internal and external cold junction compensation are supported. External compensation requires a Pt100 sensor on channel 0.

Q4: Can I use this module in high-temperature environments?
A4: Yes. It operates within 0 to 60 °C and can be stored at -25 to 70 °C.

Q5: What is the resolution of the analog-to-digital conversion?
A5: The module uses a 16-bit A/D converter offering 0 to 65535 counts resolution.

Q6: What terminal block is used for wiring?
A6: The TSX BLY 01 screw terminal block is used for sensor connections.

Q7: How often does the module update input data?
A7: The complete cycle for all four channels is 550 ms.

Q8: What standards and certifications does this module comply with?
A8: It complies with IEC 584, IEC 751, DIN 43710, NFC 42-330, and carries CE, DNV, BV, ABS, RMRS, RINA, GL, and LR certifications.

Tags
Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message