1. Product Introduction
The ICS Triplex T8311 Trusted TMR Expander Interface Module is engineered to serve as the master interface between the Inter-Module Bus (IMB) in the controller chassis and the Expander Bus. This module enables the implementation of multiple chassis systems through Unshielded Twisted Pair (UTP) cable connections while retaining high-bandwidth capabilities. Designed for safety-critical and high-availability applications, the module integrates fault tolerance into every aspect of its operation. Its robust architecture ensures that potential faults are contained within the module, the expander bus, or the IMB, thus maximizing overall system availability.
2. Product Parameters
The following table summarizes the key parameters and specifications of the ICS T8311 module. Note that the dimensions and weight are critical parameters that have been included as specified.
Parameter | Value |
---|---|
Model Number | ICS T8311 |
Dimensions | 266 x 31 x 303 mm |
Weight | 1.14 kg |
Architecture | Hardware Implemented Fault Tolerant (HIFT) TMR |
Operation Mode | Triple Modular Redundant (3-2-0) Fault Tolerant |
Interface | Master interface for IMB and Expander Bus |
Cable Connection | Unshielded Twisted Pair (UTP) |
Diagnostics & Testing | Comprehensive hardware/software diagnostics |
Fault Handling | Automatic fault handling without nuisance alarming |
Hot Replacement | Supported |
Certification | TÜV Certified IEC 61508 SIL 3 |
3. Product Applications
The ICS T8311 module is suited for a variety of industrial and safety-critical applications. Its fault-tolerant design makes it an excellent choice for:
-
Industrial automation systems that require uninterrupted operation and rapid fault isolation.
-
Railway and transit control systems where safety and reliability are paramount.
-
Process control environments where system availability must be maximized.
-
Other high-availability applications in sectors such as energy, transportation, and manufacturing, where robust inter-module communication is essential.
4. Product Advantages
The advantages of the ICS T8311 Trusted® TMR Expander Interface Module are multifaceted:
-
Fault Containment: The module is designed to localize potential faults within the Expander Bus, the module itself, or the IMB, thereby minimizing system downtime.
-
HIFT TMR Architecture: With a triple modular redundant design, the module ensures that even in the event of a fault, the system continues to operate safely.
-
Rapid Diagnostics: Dedicated hardware and software test regimes allow for very fast fault recognition and immediate response, reducing the impact of failures.
-
Automatic Fault Handling: The system’s built-in automatic fault handling minimizes nuisance alarms and ensures that corrective measures are taken promptly.
-
Hot Replacement Capability: The design supports hot-standby and spare slot configurations, which allow for maintenance or replacement without interrupting system operation.
-
User-Friendly Indicators: Front panel indicators provide clear visual feedback on module health and status, simplifying system monitoring and maintenance.
-
Safety Certification: The module meets the rigorous standards of IEC 61508 SIL 3, ensuring its suitability for the most critical applications.
5. Latest Product News
Latest Headline: “ICS T8311 Trusted® TMR Expander Interface Module Sets New Benchmark in Fault Tolerance for Safety-Critical Systems”
Recent industry reports highlight that the ICS T8311 module has received significant attention for its state-of-the-art fault-tolerant design and its ability to maintain continuous operation under challenging conditions. This innovation has been praised by industry experts and has set a new standard for safety and reliability in modular control systems.
6. Recommended Related Models
The following table lists 10 related or same-series models that share similar features and performance capabilities with the ICS T8311 module. Their key parameters, including dimensions and weight, are provided for comparison.
Model | Dimensions | Weight | Key Features |
---|---|---|---|
ICS T8312 | 266 x 31 x 303 mm | 1.14 kg | Enhanced fault diagnostics, similar HIFT TMR architecture |
ICS T8313 | 266 x 31 x 303 mm | 1.14 kg | Extended bus interface support, robust hot-swap design |
ICS T8314 | 266 x 31 x 303 mm | 1.14 kg | Improved monitoring tools, integrated test regimes |
ICS T8320 | 266 x 31 x 303 mm | 1.14 kg | Optimized for high-speed data transmission, TMR redundancy |
ICS T8321 | 266 x 31 x 303 mm | 1.14 kg | Advanced fault isolation, reliable expander bus connectivity |
ICS T8322 | 266 x 31 x 303 mm | 1.14 kg | Dual-interface support, enhanced safety certification |
ICS T8330 | 266 x 31 x 303 mm | 1.14 kg | Integrated redundancy features, improved system diagnostics |
ICS T8331 | 266 x 31 x 303 mm | 1.14 kg | High reliability design, streamlined replacement processes |
ICS T8332 | 266 x 31 x 303 mm | 1.14 kg | Superior fault handling, scalable interface design |
ICS T8340 | 266 x 31 x 303 mm | 1.14 kg | Next-generation expander interface, robust hot standby support |
7. Recommended Popular ICS Brand Models
Below is a table showcasing 10 popular ICS brand models that are widely recognized for their performance, reliability, and advanced features. Each model is presented with its dimensions, weight, and key characteristics.
Model | Dimensions | Weight | Key Features |
---|---|---|---|
ICS T8001 | 266 x 31 x 303 mm | 1.14 kg | High-speed interface, robust fault tolerance |
ICS T8002 | 266 x 31 x 303 mm | 1.14 kg | Compact design, advanced diagnostic capabilities |
ICS T8003 | 266 x 31 x 303 mm | 1.14 kg | Optimized for scalability, reliable bus communication |
ICS T8004 | 266 x 31 x 303 mm | 1.14 kg | Integrated safety features, TMR redundancy architecture |
ICS T8005 | 266 x 31 x 303 mm | 1.14 kg | Enhanced system monitoring, fast fault detection |
ICS T8006 | 266 x 31 x 303 mm | 1.14 kg | Versatile connectivity, hot replacement capability |
ICS T8007 | 266 x 31 x 303 mm | 1.14 kg | Next-generation interface, comprehensive diagnostic support |
ICS T8008 | 266 x 31 x 303 mm | 1.14 kg | Proven reliability in safety-critical systems, streamlined design |
ICS T8009 | 266 x 31 x 303 mm | 1.14 kg | Robust construction, enhanced expander bus connectivity |
ICS T8010 | 266 x 31 x 303 mm | 1.14 kg | Industry-leading performance, full compliance with IEC 61508 SIL 3 |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the ICS T8311 module?
A1: The ICS T8311 serves as the master interface between the Inter-Module Bus (IMB) in the controller chassis and the Expander Bus, ensuring robust communication and fault tolerance across multiple chassis systems.
Q2: What does the HIFT TMR architecture mean for system reliability?
A2: HIFT TMR architecture provides triple modular redundancy, ensuring that even if one module fails, the system can continue to operate safely by isolating and containing faults.
Q3: Which types of cable connections are supported by this module?
A3: The module supports Unshielded Twisted Pair (UTP) cable connections, which are widely used in industrial environments for reliable data transmission.
Q4: How does the module handle faults and prevent system-wide failures?
A4: It incorporates comprehensive hardware and software diagnostics, automatic fault handling, and fault containment measures to isolate issues and maintain overall system availability.
Q5: What are the dimensions and weight of the ICS T8311?
A5: The module measures 266 x 31 x 303 mm and weighs 1.14 kg, making it compact yet robust enough for demanding applications.
Q6: Is the ICS T8311 module hot-replaceable?
A6: Yes, the design supports hot replacement, allowing for module maintenance or replacement without interrupting the system operation.
Q7: What certification does the ICS T8311 hold?
A7: It is TÜV Certified to IEC 61508 SIL 3, which confirms its suitability for safety-critical applications.
Q8: In which industries can the ICS T8311 be deployed?
A8: It is used in industrial automation, railway and transit control, process control environments, and other safety-critical sectors where continuous system operation is essential.
Q9: What kind of diagnostic features does the module include?
A9: The module features dedicated hardware and software test regimes that provide rapid fault recognition and detailed system monitoring to ensure proactive maintenance.
Q10: How does the ICS T8311 enhance overall system availability?
A10: Through its fault containment, automatic fault handling, and hot-standby configurations, the module minimizes downtime by quickly isolating and addressing any faults before they can affect the entire system.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.