Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Technical Specifications
Parameter | Details |
---|---|
Model Number | FC-SCNT02 |
Description | SC S300 Safety Controller, SIL3 certified |
Safety Standard Compliance | TÜV certified for SIL3 |
Compatibility | Fully backward-compatible with FC-SCNT01 |
Redundancy Support | Compatible with redundant SMSC configuration |
Protocol Support | DNP3 Outstation protocol (licensed feature) |
Release Compatibility | Supported from Safety Manager SC R200.2 and higher |
Use Case | Process safety, wellhead control, SCADA integration |
Memory | Increased internal memory over FC-SCNT01 |
Hot Swap Capability | Yes, can replace FC-SCNT01 online |
Controller Communication | Compatible with ControlEdge RTU or Experion acting as DNP3 Master |
Mounting Type | DIN-rail / rack-mounted, pin-to-pin compatible with FC-SCNT01 |
Dimensions | 127 x 95 x 60 mm |
Weight | 0.5 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the purpose of the FC-SCNT02 controller?
A1: The FC-SCNT02 is a high-integrity SIL3-certified controller designed for Honeywell’s Safety Manager SC systems, serving as the central logic processing unit in safety-critical applications.
Q2: Can the FC-SCNT02 replace the FC-SCNT01 module in existing systems?
A2: Yes. The FC-SCNT02 is fully backward-compatible and can replace FC-SCNT01 online without requiring changes to the configuration or wiring.
Q3: Is the FC-SCNT02 compatible with redundant controller configurations?
A3: Yes. It functions alongside another FC-SCNT01 or FC-SCNT02 in redundant Safety Manager SC controller setups.
Q4: What protocol support is added in the FC-SCNT02?
A4: The module introduces support for the DNP3 Outstation protocol, enabling integration with DNP3 Masters such as Experion servers or ControlEdge RTUs.
Q5: Does the DNP3 feature require additional licensing?
A5: Yes. The DNP3 protocol in FC-SCNT02 is a licensed feature, with small, medium, and large licenses based on the number of outstations.
Q6: From which firmware release is the FC-SCNT02 supported?
A6: The FC-SCNT02 is supported from Safety Manager SC firmware release R200.2 and above.
Q7: What are the memory enhancements in FC-SCNT02 over its predecessor?
A7: FC-SCNT02 includes expanded memory compared to the FC-SCNT01, enabling support for more complex configurations and DNP3 functionality.
Q8: Is there a need to reconfigure Safety Builder projects when replacing FC-SCNT01 with FC-SCNT02?
A8: No reconfiguration is needed. FC-SCNT02 is designed to be a drop-in replacement and will operate identically within existing configurations.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.