The Honeywell CC-TAOX11 51308353-175 is a high-performance analog output module designed for use in Experion Series-C I/O systems. It provides reliable and precise analog output signals, supporting industrial automation and process control applications. Featuring redundant configurations, advanced diagnostics, and high accuracy, this module is ideal for critical control applications in various industries.
Product Features
- High Accuracy: Supports 4-20 mA current outputs with minimal deviation.
- Redundant Design: Ensures high availability and fault tolerance.
- Fast Response Time: Settles to 1% of final value within 80 ms.
- Diagnostics & Protection: Features open-wire detection, short-circuit protection, and self-diagnostics.
- Flexible Configuration: Allows configuration for fail-safe or hold-last-value modes.
- Compact & Lightweight: Designed for efficient space utilization in control cabinets.
Product Specifications
Parameter | Specification |
---|---|
Model | CC-TAOX11 51308353-175 |
Output Type | 4-20 mA current loop |
Channels | 16 |
Output Accuracy | ± 0.35% full scale |
Max Load Resistance | 800Ω |
Response Time | 80 ms (settles within 1% of final value) |
Redundancy | Yes |
Voltage Compliance | 16V max |
Open Circuit Voltage | 22V max |
Temperature Range | -40°C to 70°C |
Dimensions | 12-inch |
Weight | 0.8 kg |
Product Advantages
- Enhanced Reliability: Built-in redundancy and fail-safe mechanisms for uninterrupted operations.
- Precision Control: High accuracy ensures stable and precise analog output performance.
- Robust Design: Resistant to harsh environments with wide temperature tolerance.
- Quick Installation & Maintenance: Plug-and-play design with modular architecture simplifies field installation.
- Cost-Effective: Reduces operational downtime and maintenance costs through self-diagnostics and protection features.
Applications
- Industrial Process Control
- Distributed Control Systems (DCS)
- SCADA Systems
- Power Plants
- Oil & Gas Industry
- Chemical & Pharmaceutical Manufacturing
- Water Treatment Plants
Latest Industry News on Analog Output Modules
- “Honeywell Expands Experion Series-C I/O to Enhance Industrial Automation” (March 2025)
- “New Innovations in Analog Output Modules: How Redundancy Improves Plant Reliability” (February 2025)
- “Advancements in 4-20 mA Output Technology for Industrial Automation” (January 2025)
Recommended Related Models
Model | Description | Channels | Output Type | Redundant Support |
---|---|---|---|---|
CC-TAOX01 | Analog Output IOTA | 16 | 4-20 mA | No |
CC-TAOX51 | Analog Output IOTA | 16 | 4-20 mA | Yes |
CC-PAOH01 | Analog Output Module with HART | 16 | 4-20 mA | Yes |
CC-PAOH51 | Analog Output Module with HART | 16 | 4-20 mA | Yes |
CC-PAOX01 | Analog Output Module | 16 | 4-20 mA | No |
CC-PAON01 | Analog Output Module | 16 | 4-20 mA | Yes |
Popular Honeywell Models
Model | Description | Application |
---|---|---|
900RSM-0200 | Redundant Switch Module | Network Communication |
FC-TSRO-0824 | Digital Output Field Termination Assembly | Digital Control |
FC-SAI-1620M | Analog Input Module | Data Acquisition |
10005/1/1 | Watchdog Module | Safety & Monitoring |
FC-PSU-UNI2450U | Power Supply Module | System Power Management |
SPS5710 51199929-100 | Power Supply Module | Industrial Power Solutions |
FAQ
FAQs (Frequently Asked Questions)
Q1: What is the purpose of the CC-TAOX11 Analog Output Module?
A1: It is used to generate precise analog signals (4-20 mA) to control field devices such as actuators, control valves, and process instrumentation.
Q2: Can the CC-TAOX11 module operate in a redundant configuration?
A2: Yes, it supports redundancy to enhance system reliability and fault tolerance.
Q3: What is the response time of this module?
A3: The module settles to 1% of its final value within 80 ms, ensuring fast and accurate process control.
Q4: How many output channels does the CC-TAOX11 provide?
A4: It supports 16 output channels, each capable of delivering a 4-20 mA signal.
Q5: What protection features does this module include?
A5: The CC-TAOX11 includes open-wire detection, short-circuit protection, and self-diagnostics to ensure safe operation.
Q6: What is the maximum load resistance supported?
A6: The module supports a maximum resistive load of 800Ω.
Q7: Can this module be used in hazardous environments?
A7: Yes, it is ruggedly designed to operate in harsh industrial conditions with wide temperature tolerance.
Q8: What power supply is required for the module?
A8: The CC-TAOX11 operates within a 24V system power range.