Welcome to TilGames!

HIMA Z7138 LED Cable Plug

HIMA Z7138 LED Cable Plug

Manufacturer:HIMA

Product Number:Z7138

Product Type:LED Cable Plug

Origin:Germany

Space Requirement:4 TE

Shipping Weight:3 kg

Views:14

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
https://www.tilgames.com/wp-content/uploads/2025/03/Z7138-7-1.jpg
https://www.tilgames.com/wp-content/uploads/2025/03/Z7138-8.jpg
https://www.tilgames.com/wp-content/uploads/2025/03/Z7138-9.jpg
https://www.tilgames.com/wp-content/uploads/2025/03/Z7138-10.jpg
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Product Introduction: HIMA Z7138 LED Cable Plug

The HIMA Z7138 LED Cable Plug is an integral component used for safe and efficient connectivity in industrial control systems. Designed to work seamlessly with HIMA safety-related modules, it ensures reliable communication and signal transfer for various industrial applications. This component is specifically engineered for use with output modules that handle resistive and inductive loads up to 500 mA (12 W) and lamp connections up to 4 W. The Z7138 is built with integrated safety features, ensuring a fail-safe operation even in the event of a system fault.


Product Parameters:

Parameter Specification
Product Type LED Cable Plug
Dimensions (H x W x D) 4 TE (Standard)
Weight 3 kg (Shipping Weight)
Connection Type 2-pole flat pin connection (2.8 x 0.8 mm)
Cable Type LiYY 16 x 0.5 mm²
Cable Length 750 mm
Rated Voltage 24 V DC (Typical)
Current Rating 500 mA (Max)
Safety Features Integrated safety shutdown, safe isolation
Operating Voltage 5 V DC: 110 mA, 24 V DC: 180 mA
Load Requirements Max 10 output modules per I/O rack

Product Features:

  • Integrated Safety Shutdown: Ensures that the output signal is cut off in case of a fault, enhancing system safety.

  • Safe Isolation: Provides electrical isolation for safe operation, particularly with high-voltage systems.

  • Test Functionality: The module includes a built-in test routine to verify the integrity of the output signals, including walking-bit tests and signal feedback.

  • Versatile Compatibility: Can handle both resistive and inductive loads, making it suitable for various industrial applications.

  • Compact Design: With a space requirement of only 4 TE, it is efficient in terms of space while providing high functionality.


Product Advantages:

  • Enhanced Safety: Designed for industrial applications requiring high safety standards, ensuring continuous system reliability.

  • Durable and Long-Lasting: Built with high-quality components that withstand the harsh industrial environment.

  • Efficient Testing: Automatic self-testing functionality minimizes downtime and ensures consistent performance.

  • Compact and Space-Saving: Saves valuable space in industrial control panels, making it suitable for dense installations.


Applications:

The HIMA Z7138 LED Cable Plug is ideal for use in various industries such as:

  • Industrial Automation: For connecting safety-related output modules that control resistive and inductive loads.

  • Process Control Systems: Used in processes requiring high safety standards, including hazardous environments.

  • Energy Generation: Employed in control systems for power plants to ensure safe and reliable communication between modules.

  • Machine Safety Systems: Vital for protecting machinery and ensuring that safety signals are maintained even in the event of a fault.


Recent News Title:

  • “HIMA Z7138 Cable Plug Enhances Safety in Industrial Automation Systems”


Recommended Models (Same Series or Related):

Model Description Key Features
HIMA Z7139 Similar LED cable plug, designed for higher current applications Higher current rating, robust construction
HIMA Z7140 Compatible with multiple output modules Designed for faster communication speeds
HIMA Z7141 Advanced cable plug for sensitive industrial equipment Enhanced insulation and shielding capabilities
HIMA Z7138-P2 Designed for two-pole connection systems Smaller, more compact design
HIMA Z7150 Suitable for larger output modules in heavy-duty environments Can handle higher loads
HIMA Z7100 Premium model designed for extreme conditions Superior safety features, ruggedized

Popular HIMA Models:

Model Description Key Features
HIMA F 3300 8-fold output module for safety applications Integrated safety shutdown, max 500 mA
HIMA F 3500 Compact safety relay for industrial control Highly reliable with a fast response time
HIMA Z7101 General-purpose LED cable plug Cost-effective, easy to install
HIMA F 3400 I/O module for real-time data processing High-accuracy measurements, fast processing
HIMA Z7120 Durable cable plug for harsh environments Water-resistant, high insulation
HIMA Z7200 Connector designed for critical system applications Features enhanced reliability and fail-safe design
FAQ

FAQ:

Q1: What is the maximum current the HIMA Z7138 LED cable plug can handle?
A1: The HIMA Z7138 can handle up to 500 mA of current.

Q2: What type of loads is the Z7138 designed to support?
A2: It is designed to support resistive loads, inductive loads, and lamp connections up to 4 W.

Q3: What is the required voltage for the HIMA Z7138 LED cable plug to operate?
A3: The required voltage for operation is 24 V DC.

Q4: Can the HIMA Z7138 LED cable plug be used in hazardous environments?
A4: Yes, it is designed for use in industrial control systems where safety and reliability are critical.

Q5: How much space is required for installation?
A5: The Z7138 requires only 4 TE of space.

Q6: Is the Z7138 cable plug suitable for all HIMA safety-related modules?
A6: Yes, it is compatible with various HIMA safety-related output modules.

Q7: Does the HIMA Z7138 LED cable plug include any safety features?
A7: Yes, it includes integrated safety shutdown and safe isolation features.

Q8: What is the maximum number of output modules that can be used in one I/O rack with the Z7138?
A8: You can use up to 10 output modules with nominal load in one I/O rack.

Tags
Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message