Product Specifications
Parameter | Description |
---|---|
Model | HIMA HIMatrix F2 DO 8 01 |
Type | Safety-related Remote I/O Module |
Number of Outputs | 8 Safety-related Relay Outputs |
Output Voltage | Up to 250 VAC / 250 VDC |
Operating Principle | De-energize to trip (can be configured for energize to trip) |
Communication Protocol | SafeEthernet |
Operating Temperature | 0°C to +60°C |
Fault Handling | FAULT LED indication, error code triggering |
Enclosure | Compact metal housing |
Dimensions | 207 x 114 x 86 mm |
Weight | 1.3 kg |
Programming Tool | ELOP II Factory |
Certification | Meets integrity requirements of corresponding test standards |
Product Introduction
The HIMA HIMatrix F2 DO 8 01 is a compact safety-related remote I/O module designed to ensure high-integrity safety applications. Equipped with 8 relay outputs, it operates on a de-energize to trip principle, ensuring that in the event of a system fault, all relay outputs switch to a safe state. If an individual channel experiences an error, only that channel is deactivated while the FAULT LED indicates the issue.
This remote I/O is designed to function seamlessly with SafeEthernet, allowing reliable communication with the connected safety controller. It is suitable for use in industrial automation systems where functional safety is critical.
Additionally, the device offers energize to trip functionality, where the relay output remains energized to execute a safety function. It is enclosed in a robust metal housing, making it highly durable for various industrial environments.
Product Applications
The HIMA HIMatrix F2 DO 8 01 is widely used in industries that require high safety integrity levels (SIL) and reliable emergency shutdown capabilities. Some of its primary applications include:
- Oil & Gas Industry – Used in Emergency Shutdown Systems (ESD) and fire & gas detection systems.
- Chemical Processing Plants – Ensures safe operation of critical processes.
- Power Plants – Applied in turbine protection systems and boiler safety controls.
- Pharmaceutical & Food Industries – Used in automation safety systems to prevent hazardous situations.
- Railway Signaling Systems – Enhances safe operations in transportation control.
- Automotive Industry – Provides reliable safety solutions in automated production lines.
Product Advantages
-
High Safety Integrity – Designed in accordance with international safety standards, ensuring a high level of reliability.
-
Dual Operating Principles – Can operate in de-energize to trip or energize to trip configurations, offering flexibility.
-
Fault Detection & Indication – Immediate FAULT LED activation and error code generation for quick diagnostics.
-
Compact & Robust Design – Metal housing ensures durability and resistance to industrial environments.
-
Seamless Communication – Integrated SafeEthernet connectivity ensures secure and high-speed data exchange.
-
Wide Voltage Support – Handles up to 250 VAC / 250 VDC, making it versatile for various applications.
-
Industry-Proven Reliability – Trusted by industries with critical safety requirements such as oil & gas, power, and rail.
-
Optimized for HIMatrix Systems – Works flawlessly with HIMA’s HIMatrix controllers for complete safety solutions.
-
Extended Temperature Range – Operates efficiently within 0°C to +60°C, suitable for diverse industrial settings.
-
Easy Integration – Designed for compatibility with ELOP II Factory programming tool for quick setup and deployment.
Latest News on HIMA HIMatrix F2 DO 8 01
- HIMA Enhances Industrial Safety with Advanced HIMatrix F2 DO 8 01 Module
- New Updates to HIMA HIMatrix Series Strengthen Safety in Process Automation
- HIMA Introduces High-Performance Remote I/O Solutions for Critical Applications
- HIMatrix F2 DO 8 01: The Next-Generation Safety Module for Hazardous Industries
- SafeEthernet-Enabled HIMatrix Modules Revolutionizing Industrial Safety
- HIMA Expands Safety Portfolio with Innovative Remote I/O Solutions
- Reliability Redefined: HIMA’s Latest Safety Modules Gain Industry Recognition
- How HIMatrix F2 DO 8 01 is Enhancing Operational Safety in the Energy Sector
- HIMA’s Commitment to Functional Safety: A Look into Advanced HIMatrix Systems
- Why Industrial Automation Leaders Are Choosing HIMatrix for Critical Applications
Recommended Related Models
Model | Description |
---|---|
F3 AIO 8/4 01 | Analog input/output module with 8 inputs and 4 outputs |
F3 DIO 8/8 01 | Digital input/output module with 8 DI and 8 DO channels |
F3 DO 8 01 | Digital output module with 8 safety-related outputs |
F3 AIO 4/2 01 | Analog I/O module with 4 AI and 2 AO channels |
F2 DO 4 01 | Compact digital output module with 4 relay outputs |
F3 CPU 01 | Central processing unit for HIMatrix systems |
F2 DIO 16/8 01 | Digital I/O module with 16 inputs and 8 outputs |
F3 DI 16 01 | Digital input module with 16 safety-related inputs |
F3 AIO 8/4 02 | Extended version of the analog I/O module |
F3 DIO 16/8 01 | High-performance digital I/O module |
Popular HIMA Models
Model | Description |
---|---|
HIMatrix F60 | High-performance safety controller |
HIMax X-CPU 01 | Scalable safety CPU for large systems |
HIMatrix F35 | Compact safety controller with integrated I/O |
HIMatrix F20 | Entry-level safety controller for small applications |
HIMax X-BUS 01 | High-speed communication module |
HIMax X-DI 32 01 | Digital input module with 32 channels |
HIMax X-DO 32 01 | Digital output module with 32 channels |
HIMatrix F1 DI 16 01 | Compact digital input module with 16 inputs |
HIMatrix F3 AI 8 01 | Analog input module with 8 channels |
HIMax X-AI 8 01 | Advanced analog input module |
FAQ
Frequently Asked Questions (FAQs)
Q1: What is the primary function of the HIMA HIMatrix F2 DO 8 01 module?
A1: It is a safety-related remote I/O module with 8 relay outputs, used for safety-critical applications in industrial automation.
Q2: Can this module operate in both “de-energize to trip” and “energize to trip” modes?
A2: Yes, it can be configured for either mode based on application requirements.
Q3: What communication protocol does it use?
A3: It uses SafeEthernet for reliable safety-related communication.
Q4: What is the maximum output voltage?
A4: It supports up to 250 VAC / 250 VDC.
Q5: What happens when a system fault occurs?
A5: All relay outputs are set to a de-energized safe state, and the FAULT LED is lit.
Q6: Is it compatible with HIMA HIMatrix controllers?
A6: Yes, it is designed to work seamlessly with HIMA HIMatrix systems.
Q7: What are its dimensions?
A7: It measures 207 x 114 x 86 mm and weighs 1.3 kg.
Q8: What industries use this module?
A8: It is commonly used in oil & gas, power plants, chemical processing, and railway signaling.
Q9: Can it be programmed with third-party software?
A9: No, it is designed for use with ELOP II Factory programming tool.
Q10: What certifications does it meet?
A10: It complies with integrity requirements of relevant safety standards.