Product Specifications
Parameter | Details |
---|---|
Product Name | HIMA HIMatrix F2 DO 16 02 |
Type | Remote I/O Module |
Number of Outputs | 16 Safety-Related Relay Outputs |
Switching Voltage | 5V – 30V AC / 60V DC |
Switching Current | 10mA – 3A (Internally Fused at 3.15A) |
Response Time | ≥ 10 ms |
Communication | 2 x RJ-45 Ethernet Ports (10BASE-T/100BASE-Tx) |
Operating Voltage | 24V DC (-15% to +20%) |
Current Consumption | Max. 0.6A |
Protection Class | IP20 |
Operating Temperature | 0°C to +60°C |
Storage Temperature | -40°C to +85°C |
Installation | DIN Rail Mounting (35 mm) |
Dimensions | 255 x 114 x 113 mm |
Weight | 2 kg |
Certification | SIL 3 (IEC 61508), PL e (EN ISO 13849-1), ATEX Zone 2, UL508, FM Approval |
Product Overview
The HIMA HIMatrix F2 DO 16 02 is a safety-related remote I/O module designed for high-integrity automation systems. It features 16 relay outputs, allowing integration into safety-critical applications. This module is part of the HIMatrix series, which is known for its high reliability and compliance with safety standards.
The F2 DO 16 02 is compatible with SILworX and ELOP II Factory programming environments, offering flexibility in safety system integration. The module supports SafeEthernet communication, making it ideal for distributed safety applications.
Applications of HIMA HIMatrix F2 DO 16 02
-
Process Industry
- Used in oil & gas, chemical plants, and power stations for safety shutdowns.
-
Railway Systems
- Certified for EN 50126/50128/50129 (SIL 4), making it suitable for railway signaling and automatic train control (ATC) systems.
-
Burner and Boiler Control
- Can be used in burner management systems with EN 298 compliance for safe fuel supply shutdown.
-
Industrial Automation
- Ensures emergency stop functions in robotics, material handling, and automated production lines.
-
Machinery Safety
- Supports Category 4 / PL e applications in machinery requiring high-level safety interlocks.
-
Maritime & Offshore Applications
- Used in ship automation and offshore oil platforms for emergency shutdowns (ESD).
Key Advantages of HIMA HIMatrix F2 DO 16 02
-
SIL 3 Certified for High Safety
- Designed for safety-critical applications, ensuring high reliability and integrity.
-
16 Independent Relay Outputs
- Each relay is electrically isolated, providing safe operation in industrial environments.
-
Flexible Programming Options
- Compatible with SILworX and ELOP II Factory, allowing integration with different safety control architectures.
-
Ethernet Communication with SafeEthernet
- Supports redundant network configurations, ensuring fault-tolerant communication.
-
ATEX Zone 2 Rated
- Suitable for hazardous environments, including oil & gas facilities.
-
Fast Response Time (≥ 10 ms)
- Ensures rapid fault detection and response, critical in emergency shutdown systems.
-
Robust Design with IP20 Protection
- Can withstand harsh industrial environments, offering long operational life.
-
Compact and Lightweight
- 255 x 114 x 113 mm and 2 kg, allowing easy installation in space-constrained areas.
-
Energy-Efficient Operation
- Low power consumption (Max. 0.6A at 24V DC), reducing overall system power load.
-
Enhanced Diagnostics via LED Indicators
- Real-time status monitoring for power, system errors, and individual outputs.
Recent News about HIMA HIMatrix F2 DO 16 02
- HIMA Expands Safety Portfolio with HIMatrix Remote I/O Solutions
- Innovations in SIL 3 Safety Systems: HIMA Introduces Advanced I/O Modules
- HIMA’s HIMatrix Series Boosts Industrial Safety for Critical Infrastructure
Recommended Related Models from the HIMatrix Series
Model Name | Description |
---|---|
F2 DO 16 01 | 16-channel digital output module with relay outputs |
F2 DI 16 01 | 16-channel digital input module for safety applications |
F2 DI 32 01 | 32-channel digital input module for expanded safety systems |
F3 AIO 8/4 01 | 8-channel analog input and 4-channel analog output module |
F3 DIO 8/8 01 | 8 digital inputs and 8 digital outputs in a single module |
F2 ETH 01 | Ethernet communication module for HIMatrix systems |
F2 CP 01 | Compact processor unit for HIMatrix remote I/O systems |
F3 USC 01 | Universal safety controller with high-speed processing |
F3 AIO 16/8 01 | 16 analog inputs and 8 analog outputs for process applications |
F2 DO 8 01 | 8-channel digital output module for smaller safety applications |
Top 10 Popular HIMA Models
Model Name | Description |
---|---|
HIMax X-CPU 01 | High-performance safety controller for large-scale applications |
HIMax F35 | Compact safety controller for decentralized automation |
HIMatrix F60 | Modular safety controller for SIL 3 applications |
HIMax X-BUS | Redundant bus communication module for safety systems |
HIMax X-SB 01 | Safety base module for HIMax controllers |
HIMax X-I/O 01 | High-speed I/O module for safety-critical processes |
HIMatrix F20 | Compact safety PLC with Ethernet communication |
HIMatrix F3 CPU 01 | High-performance CPU for HIMatrix systems |
HIMax X-DI 32 01 | 32-channel digital input module for safety monitoring |
HIMax X-DO 16 01 | 16-channel digital output module for safety-critical control |
FAQ
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.