Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Overview
The HIMA F3 AIO 8/4 01 is a safety-related Remote I/O module that is part of the HIMatrix system, certified for applications up to SIL 3 (IEC 61508 / IEC 61511) and SIL 4 (EN 50126/28/29). Housed in a compact IP20-rated enclosure, this module offers 8 analog inputs and 4 analog outputs and communicates via safeethernet with a central HIMax or HIMatrix controller. It is ideal for applications in demanding safety environments, including railway systems, chemical plants, and Ex Zone 2 environments.
The analog inputs are fully safety-rated, while the analog outputs are non-safety-related but can be configured for safety using output monitoring logic.
Product Specifications
General Parameters
Parameter | Specification |
---|---|
Model | F3 AIO 8/4 01 |
Analog Inputs | 8 channels (non-galvanically isolated) |
Analog Outputs | 4 channels (non-safety-related, monitored logic) |
Communication | Safeethernet (2 x RJ-45, integrated switch) |
Supply Voltage | 24 VDC (-15% to +20%) |
Power Consumption | Max 0.8 A; idle approx. 0.4 A |
Protection Class | IP20 |
Operating Temperature | 0…+60 °C |
Storage Temperature | -40…+85 °C |
Certification | SIL 3, PL e, Cat. 4, SIL 4 (railway) |
Dimensions (W x H x D) | 207 x 114 x 97 mm |
Weight | Approx. 1 kg |
Analog Input Specifications
Parameter | Specification |
---|---|
Number of Inputs | 8 |
Signal Types | 0–10 V, 0/4–20 mA (with external shunt) |
Input Resistance | > 2 MΩ |
Accuracy (25°C) | ±0.1% of full scale |
Safety-Related Accuracy | ±2% |
Digital Resolution | 12-bit |
Sampling Time | Approx. 45 µs |
Analog Output Specifications
Parameter | Specification |
---|---|
Number of Outputs | 4 |
Signal Type | 0–21 mA |
Load Impedance | Max. 600 Ω |
Accuracy (25°C) | ±0.1% of full scale |
Safety Configuration | Optional via logic + analog input readback |
Digital Resolution | 12-bit |
Product Features
-
8 analog inputs with transmitter supply for voltage or current signals.
-
4 analog outputs that can be configured as safety-rated via feedback.
-
Line monitoring for both short-circuit and open-circuit conditions.
-
Safeethernet communication with dual redundant RJ-45 ports.
-
Integrated switch enables flexible topologies without external hardware.
-
Designed for use in Zone 2 hazardous areas.
-
Multiple model variants supporting temperatures as low as -25°C or subsea compliance.
Product Advantages
-
High safety integrity: TÜV-certified to SIL 3/4, Cat. 4, PL e.
-
Flexible configuration: Compatible with both SILworX and ELOP II Factory software.
-
Durability: Designed to retain metrological accuracy over 10 years.
-
Adaptability: Available in variants for extreme environments and railway standards.
-
Compact size: Space-efficient design for control cabinets.
-
Proven compatibility: Works seamlessly within HIMatrix and HIMax systems.
Application Areas
-
Process Automation (Oil & Gas, Chemicals)
-
Railway Signaling and Safety Systems
-
Power Generation and Distribution
-
Subsea Applications (F3 AIO 8/4 012 variant)
-
Industrial Machinery Control
-
Functional Safety Zones (Zone 2/ATEX)
Latest Report Title
“Enhanced Remote Safety Monitoring with HIMA F3 AIO 8/4 01: SIL 3/4 Compliance in Harsh Environments”
Related Models (Same Series or Function)
Model | Description | Inputs | Outputs | Temp. Range | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
F3 AIO 8/4 011 | Extended temp. (-20…+60°C), lacquered board | 8 AI | 4 AO | -20…+60 °C | 207 x 114 x 97 | 1 kg |
F3 AIO 8/4 012 | Subsea type with stainless steel housing | 8 AI | 4 AO | -20…+60 °C | 207 x 114 x 97 | 1.4 kg |
F3 AIO 8/4 014 | Railway compliant (-25…+70°C), vibration resistant | 8 AI | 4 AO | -25…+70 °C | 207 x 114 x 97 | 1 kg |
F3 AIO 8/4 01 (SWX) | SILworX compatible variant | 8 AI | 4 AO | 0…+60 °C | 207 x 114 x 97 | 1 kg |
F3 AIO 8/4 011 SWX | SILworX + extended temp. (-20 °C) | 8 AI | 4 AO | -20…+60 °C | 207 x 114 x 97 | 1 kg |
F3 AIO 8/4 014 SWX | SILworX + railway certification | 8 AI | 4 AO | -25…+70 °C | 207 x 114 x 97 | 1 kg |
Popular HIMA Models
Model | Description | Function Type | Dimensions (mm) | Weight |
---|---|---|---|---|
F8650X | HIMax Safety Controller | CPU/controller | 230 x 173 x 130 | 2.1 kg |
F35 | Compact Safety Controller | Controller | 170 x 114 x 97 | 1.5 kg |
F3226 | Analog Input Module | 16 AI, SIL 3 | 124 x 114 x 97 | 1.2 kg |
F8627X | Digital Input/Output Module | 32 DI/32 DO | 230 x 173 x 130 | 2.2 kg |
F3236 | 16-channel Analog Output Module | 16 AO, non-SIL | 124 x 114 x 97 | 1.2 kg |
F8621X | Communication Module (Profibus, Modbus) | Comm Interface | 230 x 173 x 130 | 2.0 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the maximum resolution of the analog inputs on the F3 AIO 8/4 01?
A1: The analog inputs offer a 12-bit resolution, providing high accuracy measurements across their range.
Q2: Can the analog outputs be used in safety-critical applications?
A2: Not directly; however, they can be used in safety applications if their output values are read back through safety-rated analog inputs and evaluated in the user logic.
Q3: What safety standards is the module certified for?
A3: It is certified for SIL 3 (IEC 61508), SIL 4 (EN 50126/28/29), PL e (EN ISO 13849-1), and Cat. 4.
Q4: Is the F3 AIO 8/4 01 suitable for Ex Zone 2 environments?
A4: Yes, it meets ATEX requirements and can be installed in Zone 2 with appropriate enclosure and mounting.
Q5: What programming tools are supported for configuring this module?
A5: Both SILworX (for OS V7+) and ELOP II Factory (for OS up to V6.x) can be used.
Q6: How are analog current measurements handled?
A6: Current measurement requires external shunt adapters such as Z7301 (250Ω) or Z7302/Z7309 (500Ω).
Q7: How long is the device’s metrological accuracy guaranteed?
A7: The device retains its measurement accuracy for up to 10 years, after which a proof test is recommended.
Q8: Can the F3 AIO 8/4 01 be installed directly on a DIN rail?
A8: Yes, it is designed for DIN rail mounting (35 mm), with optional mounting plate use for subsea variant.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.