Welcome to TilGames!

GE IC693ALG442 Series 90-30 PLC Analog Current/Voltage Combination Module

GE IC693ALG442 Series 90-30 PLC Analog Current/Voltage Combination Module

Manufacturer:GE Fanuc

Product Number:IC693ALG442

Product Type:Analog Current/Voltage Combination Module

Origin:USA

Dimensions:51 x 127 x 127 mm

Weight:1.5 Kg

Views:8

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
https://www.tilgames.com/wp-content/uploads/2025/04/IC693ALG442-2-1.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/IC693ALG442-3.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/IC693ALG442-4.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/IC693ALG442.jpg
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Product Description:

The IC693ALG442 is an Analog Current/Voltage Combination Input/Output Module for the GE Series 90-30 PLC system. This module provides 4 differential input channels that can either be configured for current or voltage inputs, and 2 single-ended output channels, capable of providing either current loop or voltage outputs. Each channel can be individually configured for the specific range required for your application.

Product Specifications:

Feature Specification
Input Channels 4 differential input channels
Output Channels 2 single-ended output channels
Voltage Input Ranges 0 to +10V (unipolar), -10 to +10V (bipolar)
Current Input Ranges 0 to 20 mA, 4 to 20 mA, 4 to 20 mA Enhanced
Voltage Output Ranges -10 to +10V (bipolar), 0 to +10V (unipolar)
Current Output Ranges 0 to 20 mA, 4 to 20 mA
Resolution (Current Input) 5 µA (1 LSB = 5 µA)
Resolution (Voltage Input) 2.5 mV (1 LSB = 2.5 mV)
Update Rate (Input) 8 milliseconds (approx. for all 4 channels)
Update Rate (Output) 4 milliseconds (approx. for both channels)
Accuracy (Voltage Input) ± 0.25% of full scale at 25°C, typical
Accuracy (Current Input) ± 0.25% of full scale at 25°C, typical
Power Supply 24V DC external supply required
Dimensions 51 x 127 x 127 mm
Weight 1.5 Kg

Product Features:

  • Configurable Inputs/Outputs: Both input and output channels can be independently configured for either voltage or current.

  • High Accuracy: The module offers precise measurements with 0.25% typical accuracy for voltage and current input modes.

  • Ramp Mode: Supports ramping functionality where output changes smoothly over time (ideal for process control).

  • Alarm Capability: Alarm limits can be configured for each input channel to detect deviations from set values.

  • Software Configurable: All configurations can be done using Logicmaster, VersaPro, or Control programming software, or via the Series 90-30 Hand-Held Programmer.

  • Diagnostic LED Indicators: Provides status updates with LEDs indicating module and user supply status.

Product Advantages:

  • Flexibility: Multiple input and output ranges for voltage and current allow for versatile applications.

  • Error Detection: Open-wire fault detection in current output modes ensures system reliability.

  • Easy Configuration: Can be easily configured through both software and hardware tools, providing convenience in setup and operation.

  • Robust Performance: Suitable for applications with high common mode rejection and low noise interference, ensuring accurate measurements even in challenging environments.

Product Applications:

  • Process Control Systems: Used in industries where precise analog signals are required for controlling machines or equipment.

  • Industrial Automation: Applied in automated systems where real-time analog data input and output are critical for operations.

  • Measurement Systems: Utilized in data logging and measurement applications where accurate voltage and current measurements are needed.

Related GE Models:

Here are six other models from the GE Series 90-30 or related:

Model Number of Input Channels Number of Output Channels Input/Output Type
IC693ALG442 4 (Differential Inputs) 2 (Single-Ended Outputs) Voltage/Current Combination
IC693ALG223 2 (Differential Inputs) 2 (Single-Ended Outputs) Voltage/Current Combination
IC693ALG440 4 (Differential Inputs) 0 Voltage Inputs
IC693ALG461 2 (Differential Inputs) 0 Voltage/Current Inputs
IC693ALG220 4 (Differential Inputs) 2 (Single-Ended Outputs) Current Loop Output
IC693ALG453 8 (Differential Inputs) 0 Voltage Inputs

Popular GE Models:

Model Input Channels Output Channels Key Features
IC693ALG440 4 Voltage Inputs 0 High precision, Voltage inputs
IC693ALG220 4 Current Inputs 2 High current loop output
IC693ALG453 8 Voltage Inputs 0 Precision input control
IC693MDL740 16 Discrete Inputs 0 Digital I/O module
IC693PWR321 1 Power Supply 0 Reliable PLC power source
IC693CPU350 N/A N/A Central processing unit
FAQ

FAQ (Frequently Asked Questions):

  1. Q: What is the default range for both the input and output channels?
    A: The default range for both input and output channels is 0 to +10V (unipolar).

  2. Q: How do I configure the IC693ALG442?
    A: Configuration is done using software such as Logicmaster or VersaPro, or via the Hand-Held Programmer.

  3. Q: What is the accuracy of the voltage input channels?
    A: The accuracy for voltage inputs is ± 0.25% of full scale at 25°C (77°F), typical.

  4. Q: Can the output channels be set to ramp mode?
    A: Yes, the output channels can be set to ramp mode to smoothly transition between values over time.

  5. Q: What is the maximum load capacitance for the output channels?
    A: The maximum load capacitance for the output channels is 1 µF.

  6. Q: What should I do if the module displays an error?
    A: If the module displays an error, check the %I status information for detailed error codes, which can indicate issues like invalid channels or improper configurations.

  7. Q: How can I detect an open-wire fault?
    A: Open-wire faults are detected automatically in current output modes, and the status is reported to the CPU.

  8. Q: Can the IC693ALG442 be used in all Series 90-30 PLC systems?
    A: Yes, the IC693ALG442 module is compatible with all Series 90-30 PLC models and can be installed in any available I/O slot.

Tags
Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message