Welcome to TilGames!

Emerson KJ2201X1-BA1 DeltaV Logic Solver

Emerson KJ2201X1-BA1 DeltaV Logic Solver

Manufacturer:Emerson

Product Number:KJ2201X1-BA1

Product Type:Logic Solver

Origin:USA

Dimensions:83.8 × 105.5 × 110 mm

Weight:1.2 kg

Views:20

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
https://www.tilgames.com/wp-content/uploads/2025/03/KJ2201X1-BA1-1.jpg
https://www.tilgames.com/wp-content/uploads/2025/03/KJ2201X1-BA1-2.jpg
https://www.tilgames.com/wp-content/uploads/2025/03/KJ2201X1-BA1-3.jpg
https://www.tilgames.com/wp-content/uploads/2025/03/KJ2201X1-BA1-4.jpg
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Product Introduction

The Emerson KJ2201X1-BA1 DeltaV Logic Solver is a critical component of Emerson’s DeltaV SIS™ (Safety Instrumented System) process safety system. Designed as a smart SIS Logic Solver, it integrates predictive field intelligence to enhance the availability and reliability of safety instrumented functions (SIFs). This SIL 3-rated device is engineered for flexible deployment, seamless compliance with IEC 61511, and scalability to fit applications ranging from isolated wellheads to large-scale ESD/fire and gas systems.

 

  • World’s First Smart SIS Logic Solver: Utilizes HART protocol for real-time diagnostics, reducing spurious trips and lifecycle costs.
  • Redundant Architecture: Features dual CPUs and parallel operation for bumpless failover, ensuring uninterrupted safety functions.
  • Cybersecurity Ready: Certified to ISA System Security Assurance (SSA) Level 1 per IEC 62443.

Product Specifications

Power & Environmental Specifications

Category Specifications
Input Power 24 VDC ±20%, 1.0 A (plus field power, 5.0 A total)
Field Power 4 A maximum (channel-dependent)
Operating Temperature -40°C to 70°C (-40°F to 158°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 5% to 95%, non-condensing
Shock Resistance 10 G, ½-sine wave for 11 ms
Vibration Resistance 1 mm peak-to-peak (5–16 Hz); 0.5 G (16–150 Hz)
Airborne Contaminants ISA-S71.04-1985 Class G3 (conformal coating applied)
Protection Rating IP20
Dimensions 83.8 × 105.5 × 110 mm (3.3 × 4.15 × 4.33 in)
Weight 1.2 kg (2.65 lbs)

Channel Configuration (16 Flexible I/O Channels)

Channel Type Key Parameters
Analog Input (HART) 4–20 mA, 0.2% accuracy, 16-bit resolution, 1500 V optical isolation
Discrete Input NAMUR/dry contact compatible, line fault detection (open/short circuit)
Discrete Output 24 VDC, 0.5 A/channel (4 A max/card), pulse testing for diagnostics
HART Two-State Output Configurable 0/4–20 mA, 12-bit resolution, open-loop detection

Key Features

  • Flexible I/O Channels: Each of the 16 channels can be configured as Analog Input, Discrete Input/Output, or HART Two-State Output.
  • Redundancy: Dual Logic Solvers operate in parallel with auto-sensing redundancy; no manual configuration required.
  • Diagnostics: Real-time monitoring of field devices via HART, with automatic proof testing and sequence-of-events recording (<1 ms resolution).
  • Scalability: Modular design supports SIL 1–3 applications without additional processors.

Advantages

  • Increased Availability: Predictive diagnostics reduce unplanned downtime by 85% (per Emerson research).
  • Regulatory Compliance: Simplifies adherence to IEC 61511 and IEC 62443 cybersecurity standards.
  • Seamless Integration: Compatible with DeltaV DCS or third-party systems via open protocols (e.g., Modbus).
  • Hot-Swap Capability: Failed units can be replaced online in safe areas without process disruption.

Applications

  • Oil & Gas: Emergency shutdown (ESD), fire and gas detection.
  • Chemical/Petrochemical: High-integrity pressure protection systems (HIPPS).
  • Power Generation: Turbine overspeed protection.
  • Pharmaceutical: Safety interlocks for batch processes.

Latest News Headlines

  • “Emerson’s DeltaV SIS Logic Solver Achieves Industry-First Cybersecurity Certification Under IEC 62443”
  • “New Case Study: DeltaV SIS Reduces Spurious Trips by 40% in Offshore Platforms”

Recommended Related Models

DeltaV SIS Series (6 Models)

Model Key Parameters Dimensions Weight
VS3202 Redundant Logic Solver with terminal block, 16 I/O channels 83.8 × 105.5 × 110mm 1.2 kg
V56051 1-wide SIS Net Terminator Assembly 50 × 30 × 20mm 0.1 kg
VE4050ETC2 8-Wide Carrier with extender cables 430 × 150 × 200mm 3.5 kg
V51508 Database Extension for SIS N/A (Software) N/A
VE3051C0 2-Wide Carrier with bus terminations 100 × 80 × 150mm 1.8 kg
SLS 1508 Non-redundant Logic Solver, 16 configurable channels 83.8 × 105.5 × 110mm 1.2 kg

Popular Emerson Models (6 Options)

Model Category Key Parameters Dimensions Weight
DeltaV PK Controller Process Controller SIL 3, 100+ function blocks, 1 ms scan time 200 × 150 × 80mm 2.5 kg
Rosemount 3051S Pressure Transmitter 0.04% accuracy, HART 7/Fieldbus 137 × 124 × 108mm 1.8 kg
Fisher DVC6200 Control Valve SIL 3, digital feedback, 100:1 turndown 300 × 200 × 150mm 5.0 kg
AMS Trex Device Asset Monitor Wireless vibration/temperature sensing 120 × 80 × 50mm 0.5 kg
Ovation SCADA Control System Redundant servers, 10k I/O points Rack-mounted Varies
Micro Motion 5700 Coriolis Flow Meter 0.1% mass flow accuracy, multi-variable output 150 × 200 × 250mm 3.2 kg
FAQ

FAQ

Q1: What is the maximum ambient temperature for the KJ2201X1-BA1?
A1: 70°C (158°F) continuous operation; prolonged use at high temperatures may reduce lifespan.

Q2: Can it operate in hazardous areas?
A2: Yes, certified for Class 1 Div 2 Groups A–D (ATEX/IECEx).

Q3: Is channel-to-channel isolation provided?
A3: No, but each channel is optically isolated from the system (1500 V tested).

Q4: How does redundancy work during a failure?
A4: The faulty unit de-energizes outputs automatically, while the standby unit continues operation without interruption.

Q5: What is the resolution of sequence-of-events recording?
A5: <1 ms; optional 0.25 ms with DeltaV Discrete Input Card.

Q6: Can field power be shared with the DeltaV controller?
A6: Not recommended; separate power supplies are advised for safety integrity.

Q7: How are firmware updates handled?
A7: Updates are applied via DeltaV engineering workstations with version control.

Q8: What certifications does it hold?
A8: SIL 3 (IEC 61508), ISA SSA Level 1, FM/CSA/ATEX for hazardous locations.

Tags
Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message