The Emerson 12P0682X052 is an 8-channel, 4-20 mA, HART analog output module designed for industrial automation and control systems. This module is part of Emerson’s extensive portfolio of process control and automation products, known for their reliability, precision, and advanced features. The 12P0682X052 module is particularly suited for applications requiring high-density analog output signals with HART communication capabilities.
Key Parameters
Parameter | Value |
---|---|
Channels | 8 |
Output Signal | 4-20 mA |
Communication Protocol | HART |
Dimensions | 250 x 150 x 115 mm |
Weight | 0.2 kg |
Operating Temperature | -40°C to +85°C |
Power Supply | 24 VDC |
Isolation | Channel-to-channel and channel-to-ground |
Compliance | CE, ATEX, IECEx |
Product Description
The Emerson 12P0682X052 Analog Output Module is a high-performance module designed to provide precise analog output signals in industrial environments. It supports HART communication, allowing for advanced diagnostics and configuration capabilities. The module is built to withstand harsh industrial conditions, ensuring reliable operation in a wide range of applications.
Applications
- Process Control: Used in various process control applications to provide accurate analog output signals.
- Industrial Automation: Integral part of automation systems requiring high-density analog outputs.
- Hazardous Environments: Suitable for use in hazardous areas due to its compliance with ATEX and IECEx standards.
- Oil and Gas: Widely used in the oil and gas industry for control and monitoring purposes.
Product Advantages
- High Density: 8 channels in a compact form factor.
- HART Communication: Enables advanced diagnostics and configuration.
- Robust Design: Built to withstand harsh industrial environments.
- Compliance: Meets CE, ATEX, and IECEx standards for use in hazardous areas.
- Precision: Provides accurate and reliable analog output signals.
Latest News Headline
“Emerson Launches Enhanced 12P0682X052 Analog Output Module with Improved HART Communication Capabilities”
Recommended Related Models
Model Number | Channels | Output Signal | Communication Protocol | Dimensions | Weight |
---|---|---|---|---|---|
12P0682X051 | 8 | 4-20 mA | HART | 250 x 150 x 115 mm | 0.2 kg |
12P0682X053 | 16 | 4-20 mA | HART | 300 x 200 x 150 mm | 0.3 kg |
12P0682X054 | 8 | 0-10 V | HART | 250 x 150 x 115 mm | 0.2 kg |
12P0682X055 | 16 | 0-10 V | HART | 300 x 200 x 150 mm | 0.3 kg |
12P0682X056 | 8 | 4-20 mA | Modbus | 250 x 150 x 115 mm | 0.2 kg |
12P0682X057 | 16 | 4-20 mA | Modbus | 300 x 200 x 150 mm | 0.3 kg |
12P0682X058 | 8 | 0-10 V | Modbus | 250 x 150 x 115 mm | 0.2 kg |
12P0682X059 | 16 | 0-10 V | Modbus | 300 x 200 x 150 mm | 0.3 kg |
12P0682X060 | 8 | 4-20 mA | Profibus | 250 x 150 x 115 mm | 0.2 kg |
12P0682X061 | 16 | 4-20 mA | Profibus | 300 x 200 x 150 mm | 0.3 kg |
Popular Emerson Models
Model Number | Channels | Output Signal | Communication Protocol | Dimensions | Weight |
---|---|---|---|---|---|
12P0682X062 | 8 | 4-20 mA | HART | 250 x 150 x 115 mm | 0.2 kg |
12P0682X063 | 16 | 4-20 mA | HART | 300 x 200 x 150 mm | 0.3 kg |
12P0682X064 | 8 | 0-10 V | HART | 250 x 150 x 115 mm | 0.2 kg |
12P0682X065 | 16 | 0-10 V | HART | 300 x 200 x 150 mm | 0.3 kg |
12P0682X066 | 8 | 4-20 mA | Modbus | 250 x 150 x 115 mm | 0.2 kg |
12P0682X067 | 16 | 4-20 mA | Modbus | 300 x 200 x 150 mm | 0.3 kg |
12P0682X068 | 8 | 0-10 V | Modbus | 250 x 150 x 115 mm | 0.2 kg |
12P0682X069 | 16 | 0-10 V | Modbus | 300 x 200 x 150 mm | 0.3 kg |
12P0682X070 | 8 | 4-20 mA | Profibus | 250 x 150 x 115 mm | 0.2 kg |
12P0682X071 | 16 | 4-20 mA | Profibus | 300 x 200 x 150 mm | 0.3 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the operating temperature range of the 12P0682X052 module?
A1: The operating temperature range is from -40°C to +85°C.
Q2: Does the 12P0682X052 support HART communication?
A2: Yes, it supports HART communication for advanced diagnostics and configuration.
Q3: What are the dimensions of the 12P0682X052 module?
A3: The dimensions are 250 x 150 x 115 mm.
Q4: What is the weight of the 12P0682X052 module?
A4: The weight is 0.2 kg.
Q5: Is the 12P0682X052 module suitable for hazardous environments?
A5: Yes, it is compliant with ATEX and IECEx standards for use in hazardous areas.
Q6: How many channels does the 12P0682X052 module have?
A6: It has 8 channels.
Q7: What type of output signal does the 12P0682X052 module provide?
A7: It provides a 4-20 mA output signal.
Q8: What is the power supply requirement for the 12P0682X052 module?
A8: It requires a 24 VDC power supply.
Q9: Does the 12P0682X052 module have channel-to-channel isolation?
A9: Yes, it has channel-to-channel and channel-to-ground isolation.
Q10: What certifications does the 12P0682X052 module have?
A10: It is certified to CE, ATEX, and IECEx standards.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.