Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Technical Specifications
Parameter | Description |
---|---|
Model | 3500/50-04-00 |
Part Number | 136703-01 |
Type | Tachometer Module with Discrete Internal Barrier and Internal Terminations |
Channels | 2 Channels |
Input Type | Proximity probes or magnetic pickups |
Input Signal Range | +10.0 V to -24.0 V |
Input Impedance | 7.15 kΩ (Internal Barrier version) |
Transducer Power Supply | 24 Vdc, max. 40 mA per channel |
Output – Recorder (Analog) | +4 to +20 mA |
Output Impedance | 550 Ω |
Voltage Compliance (Output) | 0 to +12 Vdc across 0 to 600 Ω load |
Resolution | 0.3662 µA/bit ±0.25% (±0.7% over temp range) |
Update Rate | Approx. 100 ms |
Power Consumption | 5.8 Watts (typical) |
Speed Range | Up to 99,999 rpm |
Input Frequency | Max. 20 kHz |
Min. Input Freq (prox) | 0.0167 Hz |
Min. Input Freq (magnetic) | 3.3 Hz |
RPM Accuracy | ±0.1 rpm (<100 rpm), ±1 rpm (100–10,000 rpm), ±0.01% (>10,000 rpm) |
RPM/Min Accuracy | ±20 rpm/min |
Alarm Setpoints | Programmable, 0–100% of full scale |
Alarm Delay – Alarm 1 | 1–60 s (1 s steps) |
Alarm Delay – Alarm 2 | 1–60 s (0.1 s steps) |
Buffered Outputs | Available per channel (short circuit and ESD protected) |
Dimensions (I/O Module) | 241.3 x 24.4 x 163.1 mm |
Weight (I/O Module) | 0.46 kg |
Environmental Rating | -20°C to +65°C |
Compliance | FCC Part 15, EN 61000-6-2, EN 61000-6-4, EN 61010-1, RoHS |
Hazardous Area Approvals | ATEX/IECEx Zone 2, cNRTLus Class I Div 2 (when installed per drawing) |
FAQ
Frequently Asked Questions (FAQ)
Q1: What type of transducers does the 3500/50-04-00 module support?
A1: The module supports 1–2 proximity probes or magnetic pickups. Magnetic pickups have limitations for certain functions like reverse rotation or zero speed detection.
Q2: Can the 3500/50-04-00 be used for overspeed protection?
A2: No. It should not be used for speed control or overspeed protection systems, as it lacks protective redundancy and required response speed.
Q3: What is the full-scale range of speed monitoring for this module?
A3: The module supports a full-scale speed measurement up to 99,999 rpm.
Q4: How are alarms managed in this module?
A4: Alarm setpoints for two levels can be configured via software. They support delay times of up to 60 seconds.
Q5: Does the module output Keyphasor signals to the system?
A5: Yes. It can supply conditioned Keyphasor signals to the rack backplane for other modules.
Q6: What is the minimum input frequency the module can detect?
A6: For proximity probes, it is 0.0167 Hz; for magnetic pickups, it is 3.3 Hz.
Q7: Is the module suitable for hazardous area installations?
A7: Yes. It holds ATEX/IECEx Zone 2 and cNRTLus Class I Div 2 certifications when installed correctly.
Q8: What is the physical size and weight of the internal barrier I/O module?
A8: The dimensions are 241.3 x 24.4 x 163.1 mm and the weight is 0.46 kg.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.