Parameter | Details |
---|---|
Total Length | 1.0 meter |
Weight | 0.23 kg |
Scale Factor | 200mV/mil (7.87V/mm) |
Linearity | Within 0.8 mils (0.02 mm) of a 200 mV/mil straight line |
Frequency Response | 0 to 10 kHz (0 to 600,000 cpm) |
Operating Temperature | Proximitor: -60°F to +212°F (-51°C to +100°C) |
Probe Operating Temp | -30°F to +350°F (-34°C to +177°C) |
Corrosion Resistance | Air, water, lube oil, ammonium hydroxide, sulfuric acid |
Relative Humidity | Up to 95%, non-condensing |
FAQ
FAQ
Q1: What is the typical application of the Bently Nevada 7200 8mm proximity probe?
A1: This proximity probe is used for non-contact displacement measurements, typically in applications such as shaft position, vibration measurement, and radial or axial vibration in rotating and reciprocating machinery.
Q2: What materials is the probe construction made of?
A2: The 8mm probe is made of polyphenylene sulfide (PPS), a high-performance plastic that can withstand harsh, wet, and chemical environments.
Q3: What is the frequency response range of this probe?
A3: The frequency response range of the 7200 8mm probe is from DC (0 Hz) to 10 kHz (600,000 cpm).
Q4: Can this probe be used in hazardous locations?
A4: Yes, the Bently Nevada 7200 8mm probe is certified by CSA, BASEEFA, and FM for use in specific hazardous locations.
Q5: What is the calibrated range of this proximity probe?
A5: The calibrated range of the 7200 8mm proximity probe is 80 mils (2.0 mm), with a measurement start point approximately 10 mils (0.25 mm) from the probe face.
Q6: What is the maximum operating temperature of the probe?
A6: The probe can operate in temperatures ranging from -30°F to +350°F (-34°C to +177°C).
Q7: What is the power supply requirement for the proximitor used with this probe?
A7: The proximitor requires a power supply of -17.5 Vdc to -26 Vdc, with a maximum consumption of 12mA.
Q8: What materials are the cables made of for this proximity probe?
A8: The integral coaxial cable used with the probe is designed for durability and may include stainless steel armor for additional protection.