ABB Bailey NTAM01 6637054A1 Infi 90 Analog Master Termination Unit

ABB Bailey NTAM01 6637054A1 Infi 90 Analog Master Termination Unit

Manufacturer:Bailey

Product Number:NTAM01 6637054A1

Product Type:Analog Master Termination Unit

Origin:Sweden (SE)

Dimensions:127 x 51 x 127 mm

Weight:0.2 kg

Views:4

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
https://www.tilgames.com/wp-content/uploads/2025/04/NTAM01-6637054A1-1.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/NTAM01-6637054A1-2.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/NTAM01-6637054A1-3.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/NTAM01-6637054A1-4.jpg
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Product Technical Overview – ABB Bailey NTAM01 6637054A1 Infi 90 Analog Master Termination Unit

1. Product Description

The ABB Bailey NTAM01 6637054A1 is an Analog Master Termination Unit designed for use in the INFI 90® Distributed Control System (DCS). It facilitates proper interface between redundant IMAMM03 Analog Master Modules and associated slave thermocouple modules (such as NTAI02) or digital operator stations (NDIS01). This unit ensures signal integrity, provides cold junction compensation, internal calibration pathways, and organizes clean physical cable terminations for plant process inputs.

It is a passive circuit board mounted on an NFTP01 Field Termination Panel and acts as a central junction for analog input signals, calibration voltage, and communication lines.


2. Product Parameters

Parameter Specification
Product Model NTAM01
Catalog Number 6637054A1
System Compatibility INFI 90® DCS
Function Analog Master Termination Unit
Compatible Master Modules IMAMM03 (Redundant Configuration)
Compatible Slave Modules NTAI02 Thermocouple Input Units
Compatible Indicator Stations NDIS01 Digital Indicator Station
Maximum NTAI02 Connections 4 units
Maximum NDIS01 Connections 4 units
Mounting Panel NFTP01 Field Termination Panel
Operating Temperature Range 0°C to 70°C (32°F to 158°F)
Relative Humidity 5% to 90% (non-condensing)
Atmospheric Pressure Sea Level to 3 km
Power Consumption 17 mA per NTAM01 unit
Power Supply +24 VDC
Dimensions 127 x 51 x 127 mm
Weight 0.2 kg
Cooling Requirements No additional cooling required
Certification CSA Certified (non-hazardous locations)
Air Quality Requirement Non-corrosive

3. Product Features

  • Supports redundant analog master configurations with IMAMM03.

  • Provides cold junction temperature compensation to NTAI02 units.

  • Routes internal calibration voltages between master and slave modules.

  • Factory-wired cable interfaces simplify installation and increase reliability.

  • Compatible with up to four NDIS01 stations or four NTAI02 slave units.

  • Compact footprint for mounting in NFTP01 panels.

  • Modular cable design allows for flexible expansions and replacements.

  • Supports both PVC and non-PVC cable variants.


4. Product Advantages

  • Redundancy Ready: Designed specifically to interface with redundant master modules, ensuring high system reliability and fault tolerance.

  • Ease of Installation: Uses factory-wired, plug-in cables, reducing manual wiring effort and installation errors.

  • Signal Integrity: Maintains analog signal accuracy with integrated cold junction compensation and shielding.

  • Scalable Architecture: Connects multiple slave and indicator units via modular cabling, supporting system expansion.

  • Maintenance Friendly: Passive hardware with minimal maintenance, easy field replaceability, and front-panel cable access.

  • Environmental Resilience: Operates in industrial conditions with high humidity, varying pressure, and wide temperature ranges.


5. Applications

  • Redundant process control loops requiring high-availability analog signal integration.

  • Distributed thermocouple temperature measurement systems in large-scale process industries.

  • Integration of operator interface stations (NDIS01) for monitoring and diagnostics.

  • Refineries, power plants, chemical manufacturing, and other process industries using the INFI 90 platform.


6. Latest Product-Related Report Title

“Enhanced Redundancy and Signal Integrity in INFI 90 Systems Using NTAM01 Termination Units”


7. Related Models in the Same Series or Function

Model Function Compatibility Dimensions (mm) Weight (kg)
NTAI02 Thermocouple Analog Input Termination Unit IMAMM03, NTAM01 127 x 51 x 127 0.2
IMAMM03 Analog Master Module NTAM01, IMASM02 216 x 40 x 180 0.8
IMASM02 Thermocouple/Millivolt Slave Module IMAMM03 216 x 40 x 180 0.6
NDIS01 Digital Indicator Station NTAM01 160 x 50 x 120 0.5
NKAI01 Cable, NTAM01 to NTAI02 (PVC) NTAM01, NTAI02 1.5 m
NKTU01 Cable, IMAMM03 to NTAM01 (PVC) NTAM01, IMAMM03 61 m

8. Popular Bailey Brand Models

Model Description System Dimensions (mm) Weight (kg)
INNPM22 Network Processing Module Symphony+ 216 x 40 x 180 0.7
IEPDH02 Ethernet Processor Module INFI 90/Symphony 216 x 40 x 180 0.75
INICT13A Network Interface Communication Termination Unit INFI 90 127 x 51 x 127 0.25
IMMFP12 Multi-Function Processor INFI 90 216 x 40 x 180 0.7
INAI01 Analog Input Module INFI 90 127 x 51 x 127 0.2
INFI90AC AC Power Supply Module INFI 90 160 x 100 x 180 1.2
FAQ

FAQ (Frequently Asked Questions)

Q1: What is the primary function of the NTAM01 unit?
A1: It provides termination, cold junction compensation, and signal calibration routing for redundant analog master configurations in INFI 90 systems.

Q2: How many NTAI02 units can be connected to one NTAM01?
A2: Up to four NTAI02 units can be connected to a single NTAM01 unit.

Q3: Is the NTAM01 compatible with NDIS01 Digital Indicator Stations?
A3: Yes, it supports up to four NDIS01 stations for digital signal display and monitoring.

Q4: Can the NTAM01 function without a redundant master module?
A4: It is primarily intended for use with redundant IMAMM03 modules but may still operate with a single master configuration.

Q5: What type of mounting panel is required for the NTAM01?
A5: It mounts on the NFTP01 Field Termination Panel using standard screws.

Q6: Does the NTAM01 require external cooling?
A6: No external cooling is necessary when installed in Bailey Control cabinets within specified limits.

Q7: What is the recommended power supply for the NTAM01 unit?
A7: A regulated +24 VDC supply is required, with a current draw of 17 mA per unit.

Q8: Can I use the NTAM01 in hazardous environments?
A8: No, the NTAM01 is CSA certified only for non-hazardous (ordinary) industrial locations.

Tags
Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message