Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Technical Overview – ABB Bailey NTAM01 6637054A1 Infi 90 Analog Master Termination Unit
1. Product Description
The ABB Bailey NTAM01 6637054A1 is an Analog Master Termination Unit designed for use in the INFI 90® Distributed Control System (DCS). It facilitates proper interface between redundant IMAMM03 Analog Master Modules and associated slave thermocouple modules (such as NTAI02) or digital operator stations (NDIS01). This unit ensures signal integrity, provides cold junction compensation, internal calibration pathways, and organizes clean physical cable terminations for plant process inputs.
It is a passive circuit board mounted on an NFTP01 Field Termination Panel and acts as a central junction for analog input signals, calibration voltage, and communication lines.
2. Product Parameters
Parameter | Specification |
---|---|
Product Model | NTAM01 |
Catalog Number | 6637054A1 |
System Compatibility | INFI 90® DCS |
Function | Analog Master Termination Unit |
Compatible Master Modules | IMAMM03 (Redundant Configuration) |
Compatible Slave Modules | NTAI02 Thermocouple Input Units |
Compatible Indicator Stations | NDIS01 Digital Indicator Station |
Maximum NTAI02 Connections | 4 units |
Maximum NDIS01 Connections | 4 units |
Mounting Panel | NFTP01 Field Termination Panel |
Operating Temperature Range | 0°C to 70°C (32°F to 158°F) |
Relative Humidity | 5% to 90% (non-condensing) |
Atmospheric Pressure | Sea Level to 3 km |
Power Consumption | 17 mA per NTAM01 unit |
Power Supply | +24 VDC |
Dimensions | 127 x 51 x 127 mm |
Weight | 0.2 kg |
Cooling Requirements | No additional cooling required |
Certification | CSA Certified (non-hazardous locations) |
Air Quality Requirement | Non-corrosive |
3. Product Features
-
Supports redundant analog master configurations with IMAMM03.
-
Provides cold junction temperature compensation to NTAI02 units.
-
Routes internal calibration voltages between master and slave modules.
-
Factory-wired cable interfaces simplify installation and increase reliability.
-
Compatible with up to four NDIS01 stations or four NTAI02 slave units.
-
Compact footprint for mounting in NFTP01 panels.
-
Modular cable design allows for flexible expansions and replacements.
-
Supports both PVC and non-PVC cable variants.
4. Product Advantages
-
Redundancy Ready: Designed specifically to interface with redundant master modules, ensuring high system reliability and fault tolerance.
-
Ease of Installation: Uses factory-wired, plug-in cables, reducing manual wiring effort and installation errors.
-
Signal Integrity: Maintains analog signal accuracy with integrated cold junction compensation and shielding.
-
Scalable Architecture: Connects multiple slave and indicator units via modular cabling, supporting system expansion.
-
Maintenance Friendly: Passive hardware with minimal maintenance, easy field replaceability, and front-panel cable access.
-
Environmental Resilience: Operates in industrial conditions with high humidity, varying pressure, and wide temperature ranges.
5. Applications
-
Redundant process control loops requiring high-availability analog signal integration.
-
Distributed thermocouple temperature measurement systems in large-scale process industries.
-
Integration of operator interface stations (NDIS01) for monitoring and diagnostics.
-
Refineries, power plants, chemical manufacturing, and other process industries using the INFI 90 platform.
6. Latest Product-Related Report Title
“Enhanced Redundancy and Signal Integrity in INFI 90 Systems Using NTAM01 Termination Units”
7. Related Models in the Same Series or Function
Model | Function | Compatibility | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|
NTAI02 | Thermocouple Analog Input Termination Unit | IMAMM03, NTAM01 | 127 x 51 x 127 | 0.2 |
IMAMM03 | Analog Master Module | NTAM01, IMASM02 | 216 x 40 x 180 | 0.8 |
IMASM02 | Thermocouple/Millivolt Slave Module | IMAMM03 | 216 x 40 x 180 | 0.6 |
NDIS01 | Digital Indicator Station | NTAM01 | 160 x 50 x 120 | 0.5 |
NKAI01 | Cable, NTAM01 to NTAI02 (PVC) | NTAM01, NTAI02 | 1.5 m | — |
NKTU01 | Cable, IMAMM03 to NTAM01 (PVC) | NTAM01, IMAMM03 | 61 m | — |
8. Popular Bailey Brand Models
Model | Description | System | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|
INNPM22 | Network Processing Module | Symphony+ | 216 x 40 x 180 | 0.7 |
IEPDH02 | Ethernet Processor Module | INFI 90/Symphony | 216 x 40 x 180 | 0.75 |
INICT13A | Network Interface Communication Termination Unit | INFI 90 | 127 x 51 x 127 | 0.25 |
IMMFP12 | Multi-Function Processor | INFI 90 | 216 x 40 x 180 | 0.7 |
INAI01 | Analog Input Module | INFI 90 | 127 x 51 x 127 | 0.2 |
INFI90AC | AC Power Supply Module | INFI 90 | 160 x 100 x 180 | 1.2 |
FAQ
FAQ (Frequently Asked Questions)
Q1: What is the primary function of the NTAM01 unit?
A1: It provides termination, cold junction compensation, and signal calibration routing for redundant analog master configurations in INFI 90 systems.
Q2: How many NTAI02 units can be connected to one NTAM01?
A2: Up to four NTAI02 units can be connected to a single NTAM01 unit.
Q3: Is the NTAM01 compatible with NDIS01 Digital Indicator Stations?
A3: Yes, it supports up to four NDIS01 stations for digital signal display and monitoring.
Q4: Can the NTAM01 function without a redundant master module?
A4: It is primarily intended for use with redundant IMAMM03 modules but may still operate with a single master configuration.
Q5: What type of mounting panel is required for the NTAM01?
A5: It mounts on the NFTP01 Field Termination Panel using standard screws.
Q6: Does the NTAM01 require external cooling?
A6: No external cooling is necessary when installed in Bailey Control cabinets within specified limits.
Q7: What is the recommended power supply for the NTAM01 unit?
A7: A regulated +24 VDC supply is required, with a current draw of 17 mA per unit.
Q8: Can I use the NTAM01 in hazardous environments?
A8: No, the NTAM01 is CSA certified only for non-hazardous (ordinary) industrial locations.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.