Product Overview
The ABB AI893 3BSC690141R1 S800 I/O Systems Analog Input Module is designed for measuring a variety of process signals with high accuracy and precision. This module features 8 differential input channels that can handle 2-wire or 3-wire RTD (Resistance Temperature Detector) sensors and Thermocouples (TC). It provides flexibility and reliability for use in hazardous environments due to the inclusion of intrinsic safety protection components on each channel, eliminating the need for external devices.
The module is well-suited for applications requiring high-precision temperature measurements, such as industrial process monitoring and control, especially where RTD and thermocouple sensors are used.
Key Features
- 8 Input Channels: Supports 2-wire or 3-wire RTD and Thermocouple sensors, allowing versatile measurement options.
- Intrinsic Safety Protection: Ensures safe operation in hazardous environments by preventing electrical hazards.
- Cold Junction Compensation: Channel 8 can be used to measure ambient temperature, serving as a cold junction for channels 1 through 7.
- Configurable Cold Junction Measurement: Users can choose to either use a fixed temperature setting or measure the cold junction temperature with a 3-wire Pt 100 sensor.
- Resolution: 15-bit + sign resolution for precise temperature readings.
- Ex Certified Inputs: The module is Ex certified for hazardous environments, ensuring compliance with safety standards.
- Compact Size: Designed for easy installation in both Ex and non-Ex applications, with compatibility with MTU units like TU890 and TU891 for efficient wiring.
- Dimensions and Weight: 45 x 102 x 119 mm, 0.16 kg, making it compact and easy to integrate into existing systems.
Applications
The ABB AI893 module is ideal for use in industries where accurate temperature measurement is essential. Some common applications include:
- Oil and Gas: Used in temperature monitoring of pipelines, tanks, and other critical equipment in hazardous environments.
- Chemicals and Pharmaceuticals: Provides precise temperature control in production processes that require RTDs or thermocouples for monitoring.
- Power Generation: Ensures accurate temperature readings in boilers, turbines, and other high-temperature environments.
- Food and Beverage: Used in temperature-sensitive processes such as pasteurization and brewing, where precise monitoring is required.
- Mining and Metals: Applicable in furnace and kiln monitoring, where temperature management is critical.
Advantages
- Versatile Input Channels: Capable of handling both RTD and thermocouple inputs, ensuring adaptability to different measurement needs.
- Safe for Hazardous Areas: Ex-certified for intrinsic safety, making it suitable for use in explosive and hazardous environments.
- High Accuracy: With 15-bit resolution, the AI893 delivers highly precise temperature data for improved control and decision-making.
- Cold Junction Compensation: Enables reliable temperature readings by compensating for ambient temperature fluctuations in thermocouple applications.
- Compact and Easy to Install: The small form factor allows for easy integration into tight spaces and is compatible with a wide range of MTUs for hassle-free wiring.
- Durability: Built to operate in harsh industrial environments, offering long-term reliability and minimal maintenance requirements.
Product Specifications
Parameter | Description |
---|---|
Input Channels | 8 differential input channels |
Supported Sensors | 2-wire or 3-wire RTD, Thermocouples |
Cold Junction Compensation | Yes, Channel 8 (ambient temperature) |
Resolution | 15-bit + sign |
Ex Certification | Yes, Ex certified for hazardous areas |
Dimensions | 45 x 102 x 119 mm |
Weight | 0.16 kg |
MTU Compatibility | TU890 (Ex), TU891 (non-Ex) |
Temperature Measurement Type | RTD, Thermocouple (with cold junction compensation) |
Recommendations for 10 Related Models
Model | Description | Input Channels | Certification | Application |
---|---|---|---|---|
AI835 | Analog input module for RTD, TC | 8 | Ex certified | Industrial |
AI840 | RTD/TC input module, 8 channels | 8 | Ex certified | Chemical |
AI820 | RTD/TC analog input, high accuracy | 4 | Non-Ex certified | Power generation |
AI820A | Analog input for 2-wire RTD, TC | 8 | Ex certified | Pharmaceuticals |
AI845 | RTD, TC measurement with enhanced safety | 8 | Ex certified | Food and beverage |
AI870 | Industrial temperature sensor input | 8 | Non-Ex certified | Mining |
AI830 | Precision temperature measurement | 4 | Ex certified | Oil & Gas |
AI850 | Analog input, wide temperature range | 8 | Ex certified | Automotive |
AI860 | Universal input for RTD, TC | 4 | Non-Ex certified | Chemicals |
AI870A | High-accuracy temperature module | 8 | Ex certified | Industrial |
Recommendations for 10 Popular ABB Models
Model | Description | Input Channels | Certification | Application |
---|---|---|---|---|
AI843 | Analog input module for S800 I/O | 8 | Ex certified | Power systems |
AI845 | Analog input for temperature sensors | 8 | Ex certified | Process control |
AI835 | Input module for temperature sensors | 8 | Ex certified | Industrial |
AI880 | Analog input, high resolution | 8 | Ex certified | Chemical industry |
AI890 | Analog input, 8 channels | 8 | Ex certified | Power generation |
AI893 | RTD/TC input, intrinsic safety | 8 | Ex certified | Hazardous areas |
AI802 | Universal RTD/TC analog input | 4 | Ex certified | Automotive |
AI830 | Input module for RTD, TC | 4 | Non-Ex certified | Pharmaceuticals |
AI815 | Universal analog input module | 4 | Ex certified | Mining |
AI880A | Precision temperature input | 8 | Non-Ex certified | Power plants |
FAQ
FAQ (Questions and Answers)
-
What is the purpose of the ABB AI893 module?
- The ABB AI893 is used for high-accuracy temperature measurement with RTD and thermocouple sensors in hazardous environments. It provides intrinsic safety protection and cold junction compensation.
-
How many channels does the AI893 module have?
- The AI893 module has 8 differential input channels.
-
What types of sensors can the AI893 support?
- The AI893 supports 2-wire or 3-wire RTD and thermocouple sensors.
-
Can the AI893 module be used in hazardous areas?
- Yes, the AI893 is Ex certified for use in hazardous environments.
-
What is cold junction compensation, and how is it implemented in the AI893?
- Cold junction compensation corrects for ambient temperature changes affecting thermocouples. In the AI893, channel 8 measures the ambient temperature for compensation.
-
What is the resolution of the AI893 module?
- The AI893 module provides a 15-bit + sign resolution.
-
Can the cold junction temperature be manually set on the AI893?
- Yes, users can set a fixed junction temperature as a parameter in the module.
-
What MTUs are compatible with the AI893 module?
- The AI893 is compatible with the TU890 (for Ex applications) and TU891 (for non-Ex applications).
-
What are the dimensions and weight of the AI893?
- The AI893 measures 45 x 102 x 119 mm and weighs 0.16 kg.
-
How can I configure the AI893 module for use with different sensor types?
- The AI893 can be configured for either 2-wire or 3-wire RTD sensors or thermocouples by adjusting the module settings according to the application needs.