Technical Specifications
Item | Specification |
---|---|
Model | AAB841-S00 S2 |
Type | Analog I/O Module |
Input Channels | 8 (non-isolated, differential) |
Output Channels | 8 (non-isolated) |
Input Signal | 1 to 5 V DC (±1 V allowable common mode voltage) |
Output Signal | 4 to 20 mA DC |
Input Resistance (Power ON) | Voltage input: ≥1 MΩ Current input: 290 Ω (20 mA) to 450 Ω (4 mA) |
Input Resistance (Power OFF) | Voltage input: ≥340 kΩ Current input: ≥500 kΩ |
Allowable Input | Voltage: ±7.5 V Current: 25 mA |
Allowable Load Resistance | 0 to 750 Ω |
Accuracy | Voltage input: ±4 mV Current input: ±16 μA Output: ±48 μA |
Data Update Period | 10 ms |
Step Response Time (Input) | 100 ms |
Step Response Time (Output) | 40 ms |
Transmitter Power Supply | 14.8 V min (at 20 mA), 26.4 V max (at 0 mA) |
Temperature Drift | ±0.1 % / 10°C |
Max Current Consumption | 410 mA (5 V DC), 290 mA (24 V DC) |
HART Communication | Supported on current input/output |
External Connection | KS cable |
Dimensions | 107.5 × 32.8 × 130 mm |
Weight | 0.3 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the main function of the AAB841-S00 S2 module?
A1: The AAB841-S00 S2 module provides 8 analog inputs (voltage or current) and 8 analog outputs (current), functioning as a dual-direction I/O interface for field control stations.
Q2: Does this module support HART communication?
A2: Yes, HART communication is supported on both input and output channels for current signal types.
Q3: Can the input mode be configured per channel?
A3: Yes, input mode (voltage or current) for each channel can be configured through software settings.
Q4: Is the AAB841-S00 S2 suitable for intrinsically safe applications?
A4: No, a Zener barrier must not be connected to this module. For intrinsically safe applications, an isolation barrier must be used.
Q5: What is the allowable load resistance for current output?
A5: The allowable load resistance for each output channel is between 0 to 750 Ω.
Q6: How often does the module update analog data?
A6: The data update cycle is 10 milliseconds for both input and output channels.
Q7: What kind of installation environment is required?
A7: The module is designed for use in Yokogawa FIO-based systems and must be installed in compatible node units or FCSs like AFV30, AFV40, AFF50, etc.
Q8: What kind of external connections are supported?
A8: The module connects via KS cables and is compatible with standard Yokogawa field wiring interfaces.