Technical Specifications
Parameter | Description |
---|---|
Module Type | Isolated Analog Input Module |
Number of Channels | 6 isolated channels |
Input Signal Ranges | Current: 0–20mA, 4–20mA, ±20mA Voltage: ±10V, 0–10V, ±5V, 0–5V, 1–5V |
Resolution | 16-bit ADC converted to IEEE 32-bit floating point or 16-bit integer |
Input Impedance (Voltage) | > 500 kΩ |
Current Input Resistance | 250 Ω ±1% |
Open Circuit Detection Time | 1 second max |
Power from Backplane | 230 mA @ 5.0V (+5% / -2.5%) 320 mA @ 3.3V (+5% / -3%) |
External 24VDC Supply | 500 mA @ 19.2–30 VDC |
Power Dissipation | 2.97 W max with 20mA inputs on all 6 channels |
Overvoltage Protection | ±35 VDC continuous |
Overcurrent Protection | ±35 mA continuous |
Channel-Channel Crosstalk | -70 dB minimum |
Isolation | 250 VAC continuous / 1500 VAC for 1 min (channel-to-channel, to chassis) |
Analog Step Response Time | 1.7 ms (0.1% of final value, excluding digital filter delay) |
Digital Filter Options | 8Hz, 12Hz, 16Hz, 40Hz, 250Hz, 1000Hz |
Filter Settling Time | 127ms (8Hz), 67ms (12Hz), 56ms (16Hz), 21ms (40Hz), 3.1ms (250Hz), 0ms (1000Hz) |
Scan Rate | New sample every 1 ms |
Accuracy | ±0.1% of range @ 25°C, ±0.2% over full temp. range |
Noise Rejection (50/60Hz) | 100 dB (8Hz & 12Hz filters) |
Diagnostic Functions | Open wire, over/under range, high/low alarms, short circuit detection |
CPU Requirement | RX3i CPU with firmware version ≥ 5.0 |
Programmer Requirement | Machine Edition ≥ Version 5.6 SP11 |
Mounting | RX3i Universal Backplane |
Dimensions (W x H x D) | 34 x 145 x 140 mm |
Weight | 0.45 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What types of input signals does the IC695ALG106-AA support?
A1: It supports both current (0–20mA, 4–20mA, ±20mA) and voltage (±10V, 0–10V, ±5V, 0–5V, 1–5V) input signals.
Q2: Can this module be used without an external 24VDC power source?
A2: No, it requires an isolated external +24 VDC power supply connected via the TB1 connector.
Q3: How is signal isolation handled between channels and the backplane?
A3: Each channel is isolated via I-coupler and transformer methods, offering 250 VAC continuous or 1500 VAC for 1 minute.
Q4: What digital filtering options are available for noise reduction?
A4: Six digital filter frequencies are available: 8Hz, 12Hz, 16Hz, 40Hz, 250Hz, and 1000Hz.
Q5: How often does the module update its input readings?
A5: It provides a new analog sample every 1 millisecond regardless of the selected filter.
Q6: Is there any built-in diagnostics for detecting faults on channels?
A6: Yes, it can detect open wires, over-range, under-range, short circuits, and alarm thresholds.
Q7: Does this module require calibration?
A7: Typical calibration interval is 12 months to maintain accuracy. Offset can be adjusted periodically.
Q8: What happens if the terminal block is not properly seated?
A8: The module will indicate a red LED (TB indicator) and disable channel operations until reconnected correctly.
Tags