Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Technical Specifications
Parameter | Specification |
---|---|
Model Number | IC200PWR102A |
Input Voltage | 85–132 VAC with jumper (120VAC nominal) 176–264 VAC without jumper (240VAC nominal) |
Input Power Consumption | 27 VA |
Input Frequency | 47 to 63 Hz |
Hold-up Time | 20 milliseconds |
Output Voltage | 3.3 VDC and 5 VDC |
Total Output Current | Maximum 1.5 A (combined) |
3.3 VDC Output Current | Maximum 1.0 A |
5 VDC Output Current | Maximum (1.5 A – current drawn from 3.3 VDC) |
Protection Features | Short circuit protection, overload protection |
Mounting Options | Mounted on CPU/NIU module or on Booster Carrier |
Application Environment | Class I, Division 2, Groups A, B, C, D; Temperature Code T4A; Ambient up to 60°C |
Dimensions (W x H x D) | 49 x 133.4 x 39 mm |
Weight | 0.118 kg |
Jumper Configuration | Jumper installed for 120VAC only. Must not be used at 240VAC. |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the purpose of the IC200PWR102A power supply in a VersaMax system?
A1: The IC200PWR102A provides the necessary backplane power to CPU, Network Interface Units (NIUs), and I/O modules in a VersaMax control system. It can serve as a primary or supplemental power supply.
Q2: Can this power supply be used with both 120VAC and 240VAC power sources?
A2: Yes, it supports both. Use a jumper for 120VAC operation. For 240VAC, do not install the jumper. Using the jumper at 240VAC will damage the unit.
Q3: What is the maximum current this power supply can deliver?
A3: The total maximum output current is 1.5 A. The 3.3 VDC output supports up to 1.0 A, and the 5 VDC output can supply the remaining current.
Q4: Is the IC200PWR102A protected against electrical faults?
A4: Yes, it has built-in protection against short circuits and overload conditions to ensure system safety and reliability.
Q5: Can the IC200PWR102A operate in hazardous environments?
A5: Yes, it is rated for Class I, Division 2 hazardous locations, Groups A, B, C, and D with a temperature code of T4A.
Q6: What happens if the jumper is incorrectly installed for a 240VAC supply?
A6: Installing the jumper when using 240VAC input will result in damage to the power supply and can create hazardous conditions.
Q7: How is the power supply mounted in the system?
A7: It is typically mounted directly on the CPU or NIU module for main power or on a Power Supply Booster Carrier for supplemental power.
Q8: What are the physical dimensions and weight of the module?
A8: The power supply measures 49 mm wide, 133.4 mm high, and 39 mm deep, with a weight of approximately 0.118 kg.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.