Products Description




Company Information | |||
[email protected] | |||
Mobile | +8613666033393 | ||
+8613666033393 | |||
13666033393 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Technical Specifications
Parameter | Specification |
---|---|
Product Model | IC200PWR002D |
Description | 24VDC Expanded 3.3V Power Supply |
Input Voltage Range | 18 to 30 VDC (24 VDC nominal) |
Input Power | 11 W |
Output Voltage | 5 VDC, 3.3 VDC |
Maximum Output Current | 1.5 A total (Max 1.0 A at 3.3 VDC) |
5VDC Output Availability | Max (1.5 A – I<sub>3.3V</sub>) A |
Holdup Time | 10 ms |
Inrush Current | 20 A at 24 VDC; 25 A at 30 VDC |
Protection Features | Short circuit, overload, reverse polarity |
Mounting Type | Direct to CPU/NIU or on Booster Carrier |
Operating Temperature | Up to 60°C ambient |
Hazardous Location Rating | Class I Div 2, Groups A, B, C, D, Temp Code T4A |
Dimensions (W x H x D) | 49 mm × 133.4 mm × 39 mm |
Weight | 0.109 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the input voltage range for the IC200PWR002D?
A1: The module accepts an input voltage ranging from 18 to 30 VDC, with a nominal input of 24 VDC.
Q2: How much output current can this power supply provide?
A2: It provides up to 1.5 A in total output current, with a maximum of 1.0 A available on the 3.3 VDC output.
Q3: Can the IC200PWR002D be used as a supplemental power supply?
A3: Yes, when mounted on a Power Supply Booster Carrier, it functions as a supplemental supply.
Q4: What type of protection does this power module offer?
A4: It includes protection against short circuits, overloads, and reverse polarity.
Q5: What is the holdup time of the IC200PWR002D?
A5: The holdup time is rated at 10 milliseconds.
Q6: Can this module operate in hazardous environments?
A6: Yes, it is certified for Class I Division 2 hazardous locations (Groups A, B, C, D) with temperature code T4A.
Q7: How is grounding handled for this power supply?
A7: The DC- is internally grounded to the frame. Therefore, floating power supplies should not be used.
Q8: What happens if 1.0 A is used on the 3.3 VDC output?
A8: Only 0.5 A would be available on the 5 VDC output since the total output must not exceed 1.5 A.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.