Welcome to TilGames!

Emerson KJ3002X1-BG2 12P1731X082 DeltaV System Thermocouple Analog Input Card

Emerson KJ3002X1-BG2 12P1731X082 DeltaV System Thermocouple Analog Input Card

Manufacturer:Emerson

Product Number:KJ3002X1-BG2 12P1731X082

Product Type:Thermocouple Analog Input Card

Origin:USA

Dimensions:107 x 41 x 105 mm

Weight:0.281 kg

Views:14

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
https://www.tilgames.com/wp-content/uploads/2025/04/KJ3002X1-BG2-12P1731X082-1.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/KJ3002X1-BG2-12P1731X082-4.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/KJ3002X1-BG2-12P1731X082-5.jpg
https://www.tilgames.com/wp-content/uploads/2025/04/KJ3002X1-BG2-12P1731X082-3.jpg
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Product Description

The KJ3002X1-BG2 (12P1731X082) is an 8-channel Thermocouple Analog Input Card designed for Emerson’s DeltaV™ M-series traditional I/O subsystem. This module is capable of direct thermocouple signal input and delivers high-accuracy temperature measurements. It features isolated channels and is engineered for zone 2 hazardous installations. The card simplifies integration and supports real-time diagnostics, ensuring reliability for critical industrial automation applications.

This I/O module interfaces with thermocouple types B, E, J, K, N, R, S, and T, offering cold junction compensation and 16-bit resolution. It’s suitable for environments requiring high precision and durability in temperature measurement.


Technical Specifications

Parameter Specification
Manufacturer Emerson Process Management
Model Number KJ3002X1-BG2
Emerson P/N 12P1731X082
Input Channels 8
Sensor Types Supported B, E, J, K, N, R, S, T, uncharacterized (mV source)
Input Type Thermocouple / mV
Cold Junction Compensation Local (on terminal block) or External
A/D Resolution 16-bit
Calibration None required
Open Sensor Detection Yes (< 70 nA), 10 seconds detection time
Common Mode Rejection 120 dB at DC/50/60 Hz
Normal Mode Rejection 60 dB at 60 Hz
Isolation Optical, 1500V DC (system), 4 channels isolated in pairs (1-4, 5-8)
Power Supply (LocalBus) 210 mA @ 12V DC
Operating Temperature -40°C to +70°C
Storage Temperature -40°C to +85°C
Relative Humidity 5% to 95%, non-condensing
Protection Rating IP20
Dimensions (HxWxD) 107 mm x 41 mm x 105 mm
Weight 0.281 kg
Mounting DIN rail, to I/O interface carrier
Compliance ISA-S71.04 G3, ATEX, IECEx, EN60079-15, EN60529, Zone 2 installation ready

Key Features

  • 8-channel thermocouple/millivolt input card with high-resolution 16-bit A/D conversion

  • Supports a wide range of thermocouple types and mV inputs

  • Cold junction compensation—local or external selectable

  • Galvanic isolation between channels and system

  • Plug-and-play support with DeltaV™ system for simplified installation

  • Robust diagnostics and open-sensor detection for improved reliability

  • No calibration required over lifetime

  • Zone 2 hazardous area compatible

  • Compact form factor with IP20 protection


Advantages

  • High Accuracy Measurement: ±0.5 to ±2.4°C reference accuracy, depending on sensor type

  • Simplified Installation: Direct plug-in to DeltaV I/O carriers; keyed terminal blocks to prevent mismatch

  • Reduced Downtime: Hot-swappable under power; diagnostics enabled

  • Wide Temperature Operating Range: Ideal for harsh environments

  • Future-Ready Design: Supports system expansion and modularity

  • Intrinsic Safety Support: Energy-limited circuits suitable for hazardous areas

  • Conformal Coating: Meets corrosion resistance standards for industrial reliability


Applications

  • Chemical processing

  • Oil & gas production (onshore/offshore)

  • Pharmaceutical manufacturing

  • Food & beverage process automation

  • Power generation (thermal, nuclear)

  • Water and wastewater treatment plants

  • Steel and metal industries


Latest Product Report Title

“DeltaV™ M-series Traditional I/O Product Data Sheet – September 2023”
Published by Emerson Process Management, this document highlights modular I/O subsystem capabilities, including thermocouple input support in the DeltaV ecosystem.


Related Emerson Models (Same Series or Function)

Model Number Description Channels Signal Type Dimensions (mm) Weight (kg)
KJ3002X1-BA1 Analog Input Card with HART 8 4-20 mA 107 x 41 x 105 0.281
KJ3002X1-BF1 RTD Input Card 8 RTD (Pt100, Ni120) 107 x 41 x 105 0.281
KJ3224X1-BA1 Thermocouple Input, Series 2 8 Thermocouple 107 x 41 x 105 0.281
KJ3225X1-BA1 RTD Input Card, Series 2 8 RTD 107 x 41 x 105 0.281
KJ3008X1-BA1 Sequence of Events Input Card 16 Discrete Input 107 x 41 x 105 0.281
KJ3006X1-BA1 Multi-Function Analog/Discrete Input 4 DI, High-speed Pulse 107 x 41 x 105 0.281

Popular Emerson DeltaV Models

Model Number Description Channels Signal Type Dimensions (mm) Weight (kg)
KJ2003X1-BA2 DeltaV MD Controller N/A Controller 107 x 41 x 105 0.320
KJ3221X1-BA1 Analog Output with HART, Series 2 8 4-20 mA 107 x 41 x 105 0.281
KJ3001X1-BB1 DI Card, Dry Contact 8 Digital Input 107 x 41 x 105 0.281
KJ3204X1-BA1 DO Card, 32 Ch, High Side, Series 2 32 Digital Output 107 x 41 x 105 0.281
KJ3004X1-BA1 Fieldbus H1 Card N/A Fieldbus Communication 107 x 41 x 105 0.281
KJ3003X1-BA1 Serial Interface Card N/A Serial Communication 107 x 41 x 105 0.281
FAQ

Frequently Asked Questions (FAQ)

Q1: What type of sensors does the KJ3002X1-BG2 support?
A1: It supports thermocouple types B, E, J, K, N, R, S, T, and uncharacterized mV inputs.

Q2: Is cold junction compensation available on this module?
A2: Yes. It includes both local (integrated) and external cold junction compensation options.

Q3: Can this card be used in Zone 2 hazardous areas?
A3: Yes, it meets ATEX and IECEx standards and is designed for use in Zone 2 locations.

Q4: Does the module require calibration?
A4: No. It is factory-calibrated and does not require periodic calibration during operation.

Q5: Is the module hot-swappable?
A5: Yes. It can be removed or inserted while system power is energized.

Q6: What is the power consumption of the card?
A6: The module typically consumes 210 mA from the 12V LocalBus.

Q7: How is the module protected against wiring errors?
A7: It includes channel and system isolation with optical decoupling and protection keys.

Q8: What is the resolution of the input signal?
A8: The module utilizes a 16-bit A/D converter for high-resolution signal processing.

Tags
Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message